Inter-laboratory trials for analysis of perfluorooctanesulfonate and perfluorooctanoate in water samples: performance and recommendations.

Sachi Taniyasu1, Kurunthachalam Kannan, Qian Wu, Karen Y Kwok, Leo W Y Yeung, Paul K S Lam, Brock Chittim, Takafumi Kida, Takumi Takasuga, Yoshiteru Tsuchiya, Nobuyoshi Yamashita.   

Abstract

The ISO 25101 (International Organization for Standardization, Geneva) describes a new international standard method for the determination of perfluorooctanesulfonate (PFOS) and perfluorooctanoate (PFOA) in unfiltered samples of drinking and surface waters. The method is based on the extraction of target analytes by solid phase extraction, solvent elution, and determination by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). For the determination of the performance of this method, more than 20 laboratories from 9 different countries participated in an inter-laboratory trial in 2006. In addition, inter-laboratory trials were conducted in 2008 and 2009 for the analysis of perfluoroalkylsubstances (PFASs), including PFOS and PFOA, in water samples by following the protocols of Japanese Industrial Standard (JIS). Overall, the repeatability coefficients of variation (i.e., within-laboratory precision) for PFOS and PFOA in all water samples were between 3 and 11%, showing a adequate precision of the ISO and JIS methods. The reproducibility coefficients of variation (i.e., between-laboratory precision) were found to vary within a range of 7-31% for surface water and 20-40% for wastewater. The recoveries of PFOS and PFOA, as a measure of accuracy, varied from 84 to 100% for surface water and from 84 to 100% for wastewater among the samples with acceptable criteria for internal standards recovery. The determined concentrations of PFASs in samples compared well with the "true" values. The results of the inter-laboratory trial confirmed that the analytical methods are robust and reliable and can be used as a standard method for the analysis of target compounds in water samples.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23498693     DOI: 10.1016/j.aca.2013.01.056

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  3 in total

1.  Quality assurance and harmonization for targeted biomonitoring measurements of environmental organic chemicals across the Children's Health Exposure Analysis Resource laboratory network.

Authors:  Kurunthachalam Kannan; Alexa Stathis; Matthew J Mazzella; Syam S Andra; Dana Boyd Barr; Stephen S Hecht; Lori S Merrill; Aubrey L Galusha; Patrick J Parsons
Journal:  Int J Hyg Environ Health       Date:  2021-03-24       Impact factor: 5.840

2.  Detection of Poly- and Perfluoroalkyl Substances (PFASs) in U.S. Drinking Water Linked to Industrial Sites, Military Fire Training Areas, and Wastewater Treatment Plants.

Authors:  Xindi C Hu; David Q Andrews; Andrew B Lindstrom; Thomas A Bruton; Laurel A Schaider; Philippe Grandjean; Rainer Lohmann; Courtney C Carignan; Arlene Blum; Simona A Balan; Christopher P Higgins; Elsie M Sunderland
Journal:  Environ Sci Technol Lett       Date:  2016-08-09

Review 3.  Trends towards Effective Analysis of Fluorinated Compounds Using Inductively Coupled Plasma Mass Spectrometry (ICP-MS).

Authors:  Ruth Lorivi Moirana; Thomas Kivevele; Josephine Mkunda; Kelvin Mtei; Revocatus Machunda
Journal:  J Anal Methods Chem       Date:  2021-02-02       Impact factor: 2.193