Literature DB >> 23498686

A novel sensor based on electropolymerization of β-cyclodextrin and L-arginine on carbon paste electrode for determination of fluoroquinolones.

Fenfen Zhang1, Shuqing Gu, Yaping Ding, Zhen Zhang, Li Li.   

Abstract

An electrochemical sensor for fluoroquinolones (FQs) based on polymerization of β-cyclodextrin (β-CD) and L-arginine (L-arg) modified carbon paste electrode (CPE) (P-β-CD-L-arg/CPE) was built for the first time. Synergistic effect of L-arg and β-CD was used to construct this sensor for quantification of these important antibiotics. Scanning electron microscope (SEM) image shows that polymer of β-CD and L-arg has been successfully modified on electrode. Electrochemical impedance spectroscopy (EIS) and cyclic voltammograms (CV) further indicate that polymer of β-CD and L-arg efficiently decreased the charge transfer resistance value of electrode and improved the electron transfer kinetic between analyte and electrode. Under the optimized conditions, this modified electrode was utilized to determine the concentrations of ciprofloxacin, ofloxacin, norfloxacin and gatifloxacin. The differential pulse voltammogram (DPV) exhibits the oxidation peak currents were linearly proportional to their concentration in the range of 0.05-100 μM for ciprofloxacin, 0.1-100 μM for ofloxacin, 0.1-40 μM for norfloxacin and 0.06-100 μM for gatifloxacin, respectively. This method was also successfully used to detect the concentrations of each drug in pharmaceutical formulations and human serum samples. In addition, this proposed fluoroquinolones sensor exhibited good reproducibility, long-term stability and fast current response.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23498686     DOI: 10.1016/j.aca.2013.01.052

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  4 in total

1.  Carbon-paste electrode modified by β-cyclodextrin as sensor for voltammetric determination of Tartrazine and Carmoisine from one drop.

Authors:  Konstantin Pliuta; Denys Snigur
Journal:  Anal Sci       Date:  2022-08-06       Impact factor: 1.967

2.  Robotic voltammetry with carbon nanotube-based sensors: a superb blend for convenient high-quality antimicrobial trace analysis.

Authors:  Somjai Theanponkrang; Wipa Suginta; Helge Weingart; Mathias Winterhalter; Albert Schulte
Journal:  Int J Nanomedicine       Date:  2015-01-27

Review 3.  Delivering precision antimicrobial therapy through closed-loop control systems.

Authors:  T M Rawson; D O'Hare; P Herrero; S Sharma; L S P Moore; E de Barra; J A Roberts; A C Gordon; W Hope; P Georgiou; A E G Cass; A H Holmes
Journal:  J Antimicrob Chemother       Date:  2018-04-01       Impact factor: 5.790

Review 4.  Cyclodextrins as Supramolecular Recognition Systems: Applications in the Fabrication of Electrochemical Sensors.

Authors:  Bronach Healy; Tian Yu; Daniele C da Silva Alves; Cynthia Okeke; Carmel B Breslin
Journal:  Materials (Basel)       Date:  2021-03-28       Impact factor: 3.623

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.