Literature DB >> 23498350

The use of patient-specific instrumentation improves the accuracy of acetabular component placement.

Leonard Buller1, Travis Smith, Jason Bryan, Alison Klika, Wael Barsoum, Joseph P Iannotti.   

Abstract

Preoperative assessment of acetabular pathology, planning of bone preparation, and implant placement using current imaging, templating, and surgical techniques are imprecise, frequently resulting in component malposition. This study compared the accuracy of 2 surgical approaches: (1) standard preoperative imaging and instrumentation and (2) a novel 3-dimensional computed tomography scan-based preoperative planning software linked to patient- and implant-specific instrumentation (PSI) for placing acetabular components. The PSI group resulted in a significant improvement (P < .05) in the average deviation of implant position (actual vs planned) for version, inclination, and total offset. Fewer clinically relevant screw perforations were observed in the PSI group. This study shows proof of concept and justifies a clinical trial comparing PSI technology with standard surgical techniques.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23498350     DOI: 10.1016/j.arth.2012.12.001

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  5 in total

Review 1.  The evolution of three-dimensional technology in musculoskeletal oncology.

Authors:  Vishaal Nanik Thadani; Muhammad Jahangir Riaz; Gurpal Singh
Journal:  J Clin Orthop Trauma       Date:  2018-07-25

2.  Spine-hip relations in patients with hip osteoarthritis.

Authors:  Charles Rivière; Stefan Lazic; Louis Dagneaux; Catherine Van Der Straeten; Justin Cobb; Sarah Muirhead-Allwood
Journal:  EFORT Open Rev       Date:  2018-02-21

3.  Improving MiniHip femoral prosthesis positioning using a cross-laser projection system in total hip arthroplasty by an anterolateral supine approach.

Authors:  Hideki Fujii; Tetsuo Hayama; Toshiomi Abe; Motoi Takahashi; Yohei Matsushita; Ryuichi Sato; Takuya Otani; Mitsuru Saito
Journal:  Int J Med Robot       Date:  2021-01-09       Impact factor: 2.547

Review 4.  Establishing a point-of-care additive manufacturing workflow for clinical use.

Authors:  Georges E Daoud; Dante L Pezzutti; Calvin J Dolatowski; Ricardo L Carrau; Mary Pancake; Edward Herderick; Kyle K VanKoevering
Journal:  J Mater Res       Date:  2021-07-06       Impact factor: 3.089

5.  Individualized reconstruction for severe periprosthetic fractures around the tumor prosthesis of knee under assistance of 3D printing technology: A case report.

Authors:  Qing Han; Xue Zhao; Chenyu Wang; Bingpeng Chen; Xiaonan Wang; Ziyan Zhang; Kesong Zhang; Yuhao Zheng; Jincheng Wang
Journal:  Medicine (Baltimore)       Date:  2018-10       Impact factor: 1.817

  5 in total