S Tudorache1, M Cara, D G Iliescu, L Novac, N Cernea. 1. Prenatal Diagnostic Unit, Emergency University Hospital, Craiova, Dolj, Romania; University of Medicine and Pharmacy Craiova.
Abstract
OBJECTIVE: To evaluate intra- and interobserver agreement for first-trimester fetal cardiac structural assessment, using two-dimensional (2D) ultrasound (2D-US) and 4D-US (4D spatiotemporal image correlation (STIC) technology), to compare the methods and to assess the advantages of adding color Doppler to each technique. METHODS: Digital videoclips (B-mode and color Doppler) and 4D-STIC volumes (gray-scale and color Doppler) from 632 pregnancies with normal fetal hearts were acquired and stored at the time of detailed first-trimester ultrasound examination. Later analysis on a randomized sample of 100 cases was performed, targeting 11 cardiac structures and features. We compared visualization of fetal heart parameters using 2D-US vs 4D-US and gray-scale vs color Doppler imaging. RESULTS: STIC volumes were considered satisfactory (adequate visualization of at least 8/11 parameters) in 78% of cases and 2D-US acquisitions in 89% of cases. The intra- and interobserver agreement was good for both 2D and 4D methods (kappa > 0.6), and the percentage overall agreement was very high using both methods (95%). 2D- and 4D-US identification of the fetal cardiac parameters did not differ significantly. The differences between gray-scale and color Doppler imaging were statistically significant in identifying similar key cardiac parameters, for both 2D- and 4D-US (P < 0.05). CONCLUSION: Both 2D and 4D methods for assessing first-trimester heart parameters are feasible and repeatable within and between observers. Color Doppler adds valuable information to both methods.
OBJECTIVE: To evaluate intra- and interobserver agreement for first-trimester fetal cardiac structural assessment, using two-dimensional (2D) ultrasound (2D-US) and 4D-US (4D spatiotemporal image correlation (STIC) technology), to compare the methods and to assess the advantages of adding color Doppler to each technique. METHODS: Digital videoclips (B-mode and color Doppler) and 4D-STIC volumes (gray-scale and color Doppler) from 632 pregnancies with normal fetal hearts were acquired and stored at the time of detailed first-trimester ultrasound examination. Later analysis on a randomized sample of 100 cases was performed, targeting 11 cardiac structures and features. We compared visualization of fetal heart parameters using 2D-US vs 4D-US and gray-scale vs color Doppler imaging. RESULTS: STIC volumes were considered satisfactory (adequate visualization of at least 8/11 parameters) in 78% of cases and 2D-US acquisitions in 89% of cases. The intra- and interobserver agreement was good for both 2D and 4D methods (kappa > 0.6), and the percentage overall agreement was very high using both methods (95%). 2D- and 4D-US identification of the fetal cardiac parameters did not differ significantly. The differences between gray-scale and color Doppler imaging were statistically significant in identifying similar key cardiac parameters, for both 2D- and 4D-US (P < 0.05). CONCLUSION: Both 2D and 4D methods for assessing first-trimester heart parameters are feasible and repeatable within and between observers. Color Doppler adds valuable information to both methods.
Authors: M Garcia; L Yeo; R Romero; D Haggerty; I Giardina; S S Hassan; T Chaiworapongsa; E Hernandez-Andrade Journal: Ultrasound Obstet Gynecol Date: 2016-03-10 Impact factor: 7.299
Authors: Raquel García Delgado; Raquel García Rodríguez; Ismael Ortega Cárdenes; Jesús M González Martín; María De Luis Alvarado; Javier Segura González; Margarita Medina Castellano; Jose A García Hernández Journal: Reprod Sci Date: 2021-02-08 Impact factor: 3.060