OBJECTIVE: To evaluate the sensitivity of multidetector computed tomography for confirming suspected foreign body aspiration into the airways in children.
METHOD: We conducted a multicentre prospective study of 303 children evaluated using multidetector computed tomography with axial analysis complemented by multiplanar reconstruction when required. The images were read by a radiologist before endoscopy then reviewed later by a senior radiologist blinded to the endoscopy findings. Endoscopy was performed routinely.
RESULTS: Foreign bodies were found by endoscopy in 70 of the 303 children. The initial multidetector computed tomography reading was 94% sensitive and 95% specific. For the review, the images for 91 patients were excluded because of motion blurring or absence of larynx visualisation; in the remaining 212 patients, sensitivity was 98% and specificity 97%.
CONCLUSION: Multidetector computed tomography as performed in our patients cannot replace endoscopy, which remains the reference standard. Nevertheless, multidetector computed tomography is sufficiently sensitive to be of value when foreign body aspiration is not considered initially or when endoscopy is likely to prove challenging.
Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23489882     DOI: 10.1016/j.ijporl.2013.02.016

Source DB:  PubMed          Journal:  Int J Pediatr Otorhinolaryngol        ISSN: 0165-5876            Impact factor:   1.675


  3 in total

1.  [Specific characteristics of chest X‑ray in childhood : Basics for radiologists].

Authors:  K Schneider
Journal:  Radiologe       Date:  2018-04       Impact factor: 0.635

2.  A rare case of bilateral bronchial foreign body.

Authors:  ZhiGang Zhao; Qian Gao; PengLong Song
Journal:  Pak J Med Sci       Date:  2015 Mar-Apr       Impact factor: 1.088

3.  Diagnosis of foreign body aspiration with ultralow-dose CT using a tin filter: a comparison study.

Authors:  Lena Gordon; Patrik Nowik; Shahla Mobini Kesheh; Marika Lidegran; Sandra Diaz
Journal:  Emerg Radiol       Date:  2020-03-09
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.