| Literature DB >> 23487507 |
Niyazi Eniseler1, Cağatay Sahan, Hikmet Vurgun, Hasan Fehmi Mavi.
Abstract
There are not enough studies that describe the isokinetic strength of professional soccer players at high angular velocities. The purpose of this study was to evaluate the seasonal changes in isokinetic strength of Turkish professional soccer players (n=14) over the course of a 24-week soccer season. The isokinetic strength of players who underwent usual soccer training and weekly competition throughout the soccer season was assessed by means of the Biodex System 3 dynamometer with the knee attachment. The peak torque of knee extensor and flexor muscles were measured at angular velocities of 60°/s, 300°/s and 500°/s. Players were tested at the beginning and end of the competitive season. While the first- and second-test measurements did not show significant changes at 60°/s and 300°/s angular velocities, at the end of the training period, players' knee strength changed significantly at 500°/s angular velocities. In addition, the H/Q ratio improved significantly for the dominant as well as non-dominant leg at 500°/s. Significant bilateral strength improvements for knee flexors were also observed at 500°/s. The findings of this study suggest that usual daily soccer training (technical, tactical, power, strength, endurance, flexibility, etc.) and weekly competition might produce changes in knee strength at high angular velocities.Entities:
Keywords: H/Q ratio; bilateral strength; isokinetic strength; seasonal changes; soccer
Year: 2012 PMID: 23487507 PMCID: PMC3588650 DOI: 10.2478/v10078-012-0017-5
Source DB: PubMed Journal: J Hum Kinet ISSN: 1640-5544 Impact factor: 2.193
Basic characteristics of the players (n=14).
| First test | Second test | |
|---|---|---|
| Age (years) | 25.8±3.9 | 26.3±3.9 |
| Body Mass (kg) | 75.1±3.3 | 75.5±4.3 |
Values are means (SD)
Overview of season-long soccer specific training content
| Type of activity | Percentage of each training component |
|---|---|
| Stretching | 10.26 |
| Strength training (power training) | 8.27 |
| Endurance training (aerobic and soccer specific endurance) | 12.91 |
| Speed, coordination (various shuffles) and agility | 18.21 |
| Plyometrics | 7.66 |
| Technical training | 11.58 |
| Tactical preparation | 7.94 |
| Games | 23.17 |
| Soccer-match | 7.61 |
General activity content of weekly training
| Mainly rest (if not, aerobic training and flexibility, sauna and massage were the choice of activities) | |
| Interval training or aerobic endurance, game | |
| Afternoon session: Circuit training that includes agility exercises and game | |
| Plyometrics or speed, tactical training and game | |
| Technical and tactical training | |
| Stretching and technical training | |
| Competition | |
Changes in angle-specific peak isokinetic knee strength of quadriceps for both D and ND legs over the 24-week soccer season
| Extensor Peak torque (Nm)
| ||||||
|---|---|---|---|---|---|---|
| 60°/s | 300°/s | 500°/s | ||||
|
| ||||||
| Dominant | Non-Dominant | Dominant | Non-Dominant | Dominant | Non-Dominant | |
| Initial test | 272.72±38.98 | 271.61±38.66 | 148.15±15.40 | 145.04±20.5 | 79.92±15.42 | 73.63±12.05 |
| Final test | 253.03±42.16 | 250.93±54.24 | 148.96±19.73 | 146.76±17.07 | 135.84±17.18 | 150.1±22.09 |
| p>0.05 | p>0.05 | p>0.05 | p>0.05 | p<0.01[ | p<0.01[ | |
n = 14; mean ± SD,
p<0.05,
p<0.01 significant differences between the initial and final test.
Changes in angle-specific peak isokinetic knee strength of hamstring for both D and ND legs over the 24-week soccer season
| Flexor Peak torque (Nm)
| ||||||
|---|---|---|---|---|---|---|
| 60°/s | 300°/s | 500°/s | ||||
|
| ||||||
| Dominant | Non-Dominant | Dominant | Non-Dominant | Dominant | Non-Dominant | |
| Initial test | 150.49±19.92 | 148.24±15.30 | 94.83±12.37 | 96.78±14.70 | 50.96±16.34 | 51.72±14.33 |
| Final test | 177.97±64.84 | 158.86±40.93 | 96.83±14.17 | 107.15±12.38 | 133.6±20.96 | 140.1±21.83 |
| p>0.05 | p>0.05 | p>0.05 | p>0.05 | p<0.01[ | p<0.01[ | |
n = 14; mean ± SD,
p<0.05,
p<0.01 significant differences between the initial test and final test.
Changes in angle-specific hamstring to quadriceps ratio (H/Q ratio) for both D and ND legs over the 24-week soccer season
| H/Q ratio (%)
| ||||||
|---|---|---|---|---|---|---|
| 60°/s | 300°/s | 500°/s | ||||
|
| ||||||
| Dominant | Non-Dominant | Dominant | Non-Dominant | Dominant | Non-Dominant | |
| Initial test | 55.40±7.80 | 55.54±6.32 | 64.1±6.98 | 67.45±10.84 | 63.53±18.23 | 72.97±15.59 |
| Final test | 62.73±23.68 | 60.81±19.13 | 75.19±11.65 | 74.05±12.62 | 98.14±19.84 | 96.36±19.15 |
| p>0.05 | p>0.05 | p<0.05[ | p>0.05 | p<0.01[ | p<0.01[ | |
n = 14; mean ± SD,
p<0.05,
p<0.01 significant differences between the initial test and final test.
Changes in angle-specific bilateral leg strength differences of extensor and flexor over the 24-week soccer season
| Bilateral strength differences ratio (%)
| ||||||
|---|---|---|---|---|---|---|
| 60°/s | 300°/s | 500°/s | ||||
|
| ||||||
| Extensor | Flexor | Extensor | Flexor | Extensor | Flexor | |
| Initial test | 9.25±6.73 | 9.27±6.73 | 12.25±4.46 | 12.57±9.88 | 14.86±7.58 | 20.73±12.71 |
| Final test | 8.80±8.97 | 8.80±8.97 | 10.46±7.53 | 8.42±5.66 | 11.37±9.09 | 7.70±6.83 |
| p>0.05 | p>0.05 | p>0.05 | p>0.05 | p>0.05 | p<0.01[ | |
n = 14; mean ± SD,
p<0.05,
p<0.01 significant differences between the initial test and final test.