Literature DB >> 23487290

Assessment of long-term results of intracranial aneurysm clipping by means of computed tomography angiography.

Przemysław Kunert1, Marek Prokopienko, Magdalena Gola, Tomasz Dziedzic, Maciej Jaworski, Andrzej Marchel.   

Abstract

BACKGROUND AND
PURPOSE: The aim of this retrospective study was to assess the effectiveness of aneurysm clipping by computed tomography angiography (CTA) in a long-term follow-up.
MATERIAL AND METHODS: The CTA examination was performed in 119 patients who had 143 aneurysms clipped. The examinations were performed 3 to 11 years (mean 6 years) after clipping using a GE Lightspeed PRO16 scanner.
RESULTS: In all cases but one, good quality CTA images, suitable for evaluation of the arteries around the clip site, were obtained. Complete aneurysm closure without neck remnant or regrowth was confirmed in 137 (96%) aneurysms. In 4 (3%) cases, neck remnants were detected (2 on the anterior communicating artery [AComA] and 2 on the middle cerebral artery [MCA]). A total clip slippage from the aneurysm dome was revealed in 1 case. One case of aneurysm re-rupture was noted, 11 years after clipping. The rebleeding was caused by AComA aneurysm regrowth. Among these 6 patients with unsatisfactory clipping, 2 required further treatment and 4 remain under observation. Nineteen 'de novo' aneurysms in other locations were found in 14 (12%) patients. Summing up all of the pathological findings in the study group, there were 18 (15%) patients who needed further management including close surveillance or re-treatment.
CONCLUSIONS: Computed tomography angiography is a simple and reliable method of aneurysm clipping evaluation. The long- term follow-up CTA confirmed the permanent and complete obliteration of 96% of the aneurysms. The rate of unsatisfactory aneurysm closure was 4%, but only 1.4% needed re-treatment during a mean follow-up of 6 years. The annual risk of aneurysm re-rupture was 0.1%.

Entities:  

Mesh:

Year:  2013        PMID: 23487290     DOI: 10.5114/ninp.2012.31549

Source DB:  PubMed          Journal:  Neurol Neurochir Pol        ISSN: 0028-3843            Impact factor:   1.621


  2 in total

1.  Gemstone spectral imaging reduced artefacts from metal coils or clips after treatment of cerebral aneurysms: a retrospective study of 35 patients.

Authors:  Yulin Jia; Jinling Zhang; Jinyu Fan; Chao Li; Yuanyuan Sun; Di Li; Xigang Xiao
Journal:  Br J Radiol       Date:  2015-09-02       Impact factor: 3.039

2.  Frequency and risk factors for postoperative aneurysm residual after microsurgical clipping.

Authors:  Kathrin Obermueller; Isabel Hostettler; Arthur Wagner; Tobias Boeckh-Behrens; Claus Zimmer; Jens Gempt; Bernhard Meyer; Maria Wostrack
Journal:  Acta Neurochir (Wien)       Date:  2020-11-20       Impact factor: 2.216

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.