Literature DB >> 23480307

Correction for isotopic interferences between analyte and internal standard in quantitative mass spectrometry by a nonlinear calibration function.

Geoffrey S Rule1, Zlatuse D Clark, Bingfang Yue, Alan L Rockwood.   

Abstract

Stable isotope-labeled internal standards are of great utility in providing accurate quantitation in mass spectrometry (MS). An implicit assumption has been that there is no "cross talk" between signals of the internal standard and the target analyte. In some cases, however, naturally occurring isotopes of the analyte do contribute to the signal of the internal standard. This phenomenon becomes more pronounced for isotopically rich compounds, such as those containing sulfur, chlorine, or bromine, higher molecular weight compounds, and those at high analyte/internal standard concentration ratio. This can create nonlinear calibration behavior that may bias quantitative results. Here, we propose the use of a nonlinear but more accurate fitting of data for these situations that incorporates one or two constants determined experimentally for each analyte/internal standard combination and an adjustable calibration parameter. This fitting provides more accurate quantitation in MS-based assays where contributions from analyte to stable labeled internal standard signal exist. It can also correct for the reverse situation where an analyte is present in the internal standard as an impurity. The practical utility of this approach is described, and by using experimental data, the approach is compared to alternative fits.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23480307     DOI: 10.1021/ac303096w

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Recommendations for the Generation, Quantification, Storage, and Handling of Peptides Used for Mass Spectrometry-Based Assays.

Authors:  Andrew N Hoofnagle; Jeffrey R Whiteaker; Steven A Carr; Eric Kuhn; Tao Liu; Sam A Massoni; Stefani N Thomas; R Reid Townsend; Lisa J Zimmerman; Emily Boja; Jing Chen; Daniel L Crimmins; Sherri R Davies; Yuqian Gao; Tara R Hiltke; Karen A Ketchum; Christopher R Kinsinger; Mehdi Mesri; Matthew R Meyer; Wei-Jun Qian; Regine M Schoenherr; Mitchell G Scott; Tujin Shi; Gordon R Whiteley; John A Wrobel; Chaochao Wu; Brad L Ackermann; Ruedi Aebersold; David R Barnidge; David M Bunk; Nigel Clarke; Jordan B Fishman; Russ P Grant; Ulrike Kusebauch; Mark M Kushnir; Mark S Lowenthal; Robert L Moritz; Hendrik Neubert; Scott D Patterson; Alan L Rockwood; John Rogers; Ravinder J Singh; Jennifer E Van Eyk; Steven H Wong; Shucha Zhang; Daniel W Chan; Xian Chen; Matthew J Ellis; Daniel C Liebler; Karin D Rodland; Henry Rodriguez; Richard D Smith; Zhen Zhang; Hui Zhang; Amanda G Paulovich
Journal:  Clin Chem       Date:  2016-01       Impact factor: 8.327

Review 2.  Determination of levodopa by chromatography-based methods in biological samples: a review.

Authors:  Ruiqi Jiang; Jiayu Yang; Shenghui Mei; Zhigang Zhao
Journal:  Anal Sci       Date:  2022-06-17       Impact factor: 1.967

3.  A validated LC-MS/MS method for the quantitation of cefazolin in human adipose tissue: Application of EMR-Lipid sorbent as an efficient sample clean-up before mass spectrometric analyses.

Authors:  Anna Siemiątkowska; Andrew Wassef; Ragui Sadek; Celine Park; Christine Yohn; Luigi Brunetti; Leonid Kagan
Journal:  J Pharm Biomed Anal       Date:  2022-02-28       Impact factor: 3.571

4.  Mitigating analyte to stable isotope labelled internal standard cross-signal contribution in quantitative liquid chromatography-tandem mass spectrometry.

Authors:  Mirjana Radovanovic; Graham Jones; Richard O Day; Peter Galettis; Ross L G Norris
Journal:  J Mass Spectrom Adv Clin Lab       Date:  2022-04-26
  4 in total