Pulsatility and the risk of nonsurgical bleeding in patients supported with the continuous-flow left ventricular assist device HeartMate II.

Omar Wever-Pinzon1, Craig H Selzman, Stavros G Drakos, Abdulfattah Saidi, Gregory J Stoddard, Edward M Gilbert, Mohamed Labedi, Bruce B Reid, Erin S Davis, Abdallah G Kfoury, Dean Y Li, Josef Stehlik, Feras Bader.   

Abstract

BACKGROUND: Bleeding is an important cause of morbidity and mortality in patients with continuous-flow left ventricular assist devices (LVADs). Reduced pulsatility has been implicated as a contributing cause. The aim of this study was to assess the effects of different degrees of pulsatility on the incidence of nonsurgical bleeding. METHODS AND
RESULTS: The Utah Transplantation Affiliated Hospitals (U.T.A.H.) heart failure and transplant program databases were queried for patients with end-stage heart failure who required support with the continuous-flow LVAD HeartMate II (Thoratec Corp, Pleasanton, CA) between 2004 and 2012. Pulsatility was evaluated by means of the LVAD parameter pulsatility index (PI) and by the echocardiographic assessment of aortic valve opening during the first 3 months of LVAD support. PI was analyzed as a continuous variable and also stratified according to tertiles of all the PI measurements during the study period (low PI: <4.6, intermediate PI: 4.6-5.2, and high PI: >5.2). Major nonsurgical bleeding associated with a decrease in hemoglobin ≥2 g/dL (in the absence of hemolysis) was the primary end point. A total of 134 patients (median age of 60 [interquartile range: 49-68] years, 78% men) were included. Major bleeding occurred in 33 (25%) patients (70% gastrointestinal, 21% epistaxis, 3% genitourinary, and 6% intracranial). In multivariable analysis, PI examined either as a categorical variable, low versus high PI (hazard ratio, 4.06; 95% confidence interval, 1.35-12.21; P=0.04), or as a continuous variable (hazard ratio, 0.60; 95% confidence interval, 0.40-0.92; P=0.02) was associated with an increased risk of bleeding.
CONCLUSIONS: Reduced pulsatility in patients supported with the continuous-flow LVAD HeartMate II is associated with an increased risk of nonsurgical bleeding, as evaluated by PI.

Entities:  

Keywords:  HeartMate II; aortic valve opening; bleeding; left ventricular assist device; pulsatility

Mesh:

Year:  2013        PMID: 23479562     DOI: 10.1161/CIRCHEARTFAILURE.112.000206

Source DB:  PubMed          Journal:  Circ Heart Fail        ISSN: 1941-3289            Impact factor:   8.790


  41 in total

1.  Further Peripheral Vascular Dysfunction in Heart Failure Patients With a Continuous-Flow Left Ventricular Assist Device: The Role of Pulsatility.

Authors:  Melissa A H Witman; Ryan S Garten; Jayson R Gifford; H Jonathan Groot; Joel D Trinity; Josef Stehlik; Jose N Nativi; Craig H Selzman; Stavros G Drakos; Russell S Richardson
Journal:  JACC Heart Fail       Date:  2015-08-12       Impact factor: 12.035

2.  Elevated Angiopoietin-2 Level in Patients With Continuous-Flow Left Ventricular Assist Devices Leads to Altered Angiogenesis and Is Associated With Higher Nonsurgical Bleeding.

Authors:  Corey E Tabit; Phetcharat Chen; Gene H Kim; Savitri E Fedson; Gabriel Sayer; Mitchell J Coplan; Valluvan Jeevanandam; Nir Uriel; James K Liao
Journal:  Circulation       Date:  2016-06-28       Impact factor: 29.690

Review 3.  Bleeding and thrombosis in chronic ventricular assist device therapy: focus on platelets.

Authors:  Antigone Koliopoulou; Stephen H McKellar; Matthew Rondina; Craig H Selzman
Journal:  Curr Opin Cardiol       Date:  2016-05       Impact factor: 2.161

4.  Gastrointestinal Bleeding Following Left Ventricular Assist Device (LVAD) Implantation: Taking the Pulse of the Problem.

Authors:  Benjamin Cassell; Vladimir M Kushnir
Journal:  Dig Dis Sci       Date:  2015-12       Impact factor: 3.199

Review 5.  Gastrointestinal bleeding after continuous-flow left ventricular device implantation: review of pathophysiology and management.

Authors:  Ashrith Guha; Carrie L Eshelbrenner; David M Richards; Howard P Monsour
Journal:  Methodist Debakey Cardiovasc J       Date:  2015 Jan-Mar

6.  HeartMate 3-a "Step" in the right direction.

Authors:  Juglans Alvarez; Vivek Rao
Journal:  J Thorac Dis       Date:  2017-05       Impact factor: 2.895

7.  Angiopoietin-2: marker or mediator of angiogenesis in continuous-flow left ventricular assist device patients?

Authors:  Lauren K Truby; Veli K Topkara
Journal:  J Thorac Dis       Date:  2016-11       Impact factor: 2.895

8.  Bleeding in continuous flow left ventricular assist device recipients: an acquired vasculopathy?

Authors:  Snehal R Patel; Sasa Vukelic; Ulrich P Jorde
Journal:  J Thorac Dis       Date:  2016-10       Impact factor: 2.895

9.  Living Without a Pulse: The Vascular Implications of Continuous-Flow Left Ventricular Assist Devices.

Authors:  Suneet N Purohit; William K Cornwell; Jay D Pal; JoAnn Lindenfeld; Amrut V Ambardekar
Journal:  Circ Heart Fail       Date:  2018-06       Impact factor: 8.790

10.  Omega-3 Therapy Is Associated With Reduced Gastrointestinal Bleeding in Patients With Continuous-Flow Left Ventricular Assist Device.

Authors:  Teruhiko Imamura; Ann Nguyen; Daniel Rodgers; Gene Kim; Jayant Raikhelkar; Nitasha Sarswat; Sara Kalantari; Bryan Smith; Ben Chung; Nikhil Narang; Colleen Juricek; Daniel Burkhoff; Tae Song; Takeyoshi Ota; Valluvan Jeevanandam; Gabriel Sayer; Nir Uriel
Journal:  Circ Heart Fail       Date:  2018-10       Impact factor: 8.790