Literature DB >> 23479309

Assessment of the fetal heart at 12-14 weeks of pregnancy using B-mode, color Doppler, and spatiotemporal image correlation via abdominal and vaginal ultrasonography.

Angélia Iara Felipe Lima1, Edward Araujo Júnior, Wellington P Martins, Luciano Marcondes Machado Nardozza, Antonio Fernandes Moron, David Baptista Silva Pares.   

Abstract

This study aimed to evaluate the effect that combining multiple ultrasonographic imaging methods has on the proportion of tests with a satisfactory fetal heart assessment at 12-14 weeks of pregnancy using B-mode, color Doppler, and spatiotemporal image correlation software (STIC) via both the abdominal and vaginal routes. This cross-sectional prospective study involved healthy pregnant women at 12-14 weeks of pregnancy with a crown-rump length (CRL) of 84 mm or shorter. The following four cardiac views were assessed: four-chamber, left and right ventricular outflow tract, and aortic arch views. The same examiner sought to identify these four views using B-mode, color Doppler, and STIC via both the vaginal and abdominal routes. The study determined the proportion of cases and the respective 95 % confidence intervals (CIs) in which all four views were identified. The presence of significant differences in comparisons between methods was analyzed using McNemar's test. Although 57 pregnant women at 12-14 weeks of pregnancy agreed to participate in the study, 4 were not included because they presented with a CRL longer than 84 mm. Thus, 53 pregnant women were thoroughly assessed and included in the analysis. The combination of B-mode, color Doppler, and STIC via both the abdominal and vaginal routes enabled the highest proportion of identification of the four views (90.6 %; 95 % CI, 79.8-95.9 %). The lowest proportions were observed when B-mode was used alone via both the vaginal route (30.2 %; 95 % CI, 19.5-43.5 %) and the abdominal route (37.7 %; 95 % CI, 25.9-51.2 %). The abdominal route showed results slightly better than those of the vaginal route with all the methods, but the differences were not statistically significant. In the vast majority of the cases, the fetal hearts were properly assessed at 12-14 weeks of pregnancy when several methods were combined using both the abdominal and vaginal routes. However, only one-third of them would have had adequate heart assessment if the B-mode via either the abdominal or the vaginal route had been used alone.

Entities:  

Mesh:

Year:  2013        PMID: 23479309     DOI: 10.1007/s00246-013-0686-4

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  15 in total

1.  Is it safe to use diagnostic ultrasound during the first trimester?

Authors:  F A Duck
Journal:  Ultrasound Obstet Gynecol       Date:  1999-06       Impact factor: 7.299

2.  Four-dimensional ultrasonography of the fetal heart with spatiotemporal image correlation.

Authors:  Luís F Gonçalves; Wesley Lee; Tinnakorn Chaiworapongsa; Jimmy Espinoza; Mary Lou Schoen; Peter Falkensammer; Marjorie Treadwell; Roberto Romero
Journal:  Am J Obstet Gynecol       Date:  2003-12       Impact factor: 8.661

3.  Fetal echocardiography during routine first-trimester screening: a feasibility study in an unselected population.

Authors:  Tommi Vimpelli; Heini Huhtala; Ganesh Acharya
Journal:  Prenat Diagn       Date:  2006-05       Impact factor: 3.050

4.  Fetal echocardiography at 11 + 0 to 13 + 6 weeks using four-dimensional spatiotemporal image correlation telemedicine via an Internet link: a pilot study.

Authors:  F Viñals; R Ascenzo; R Naveas; I Huggon; A Giuliano
Journal:  Ultrasound Obstet Gynecol       Date:  2008-06       Impact factor: 7.299

5.  Accuracy of four-dimensional spatiotemporal image correlation echocardiography in the prenatal diagnosis of congenital heart defects.

Authors:  M Bennasar; J M Martínez; O Gómez; J Bartrons; A Olivella; B Puerto; E Gratacós
Journal:  Ultrasound Obstet Gynecol       Date:  2010-10       Impact factor: 7.299

6.  Role of ultrasonography in early gestation in the diagnosis of congenital heart defects.

Authors:  Reem S Abu-Rustum; Linda Daou; Sameer E Abu-Rustum
Journal:  J Ultrasound Med       Date:  2010-05       Impact factor: 2.153

7.  Prenatal screening for congenital heart disease with four-chamber and outflow-tract views: a multicenter study.

Authors:  G Oggè; P Gaglioti; S Maccanti; F Faggiano; T Todros
Journal:  Ultrasound Obstet Gynecol       Date:  2006-11       Impact factor: 7.299

8.  Standardization of the first-trimester fetal cardiac examination using spatiotemporal image correlation with tomographic ultrasound and color Doppler imaging.

Authors:  S Turan; O M Turan; K Ty-Torredes; C R Harman; A A Baschat
Journal:  Ultrasound Obstet Gynecol       Date:  2009-06       Impact factor: 7.299

9.  Population-based study of antenatal detection of congenital heart disease by ultrasound examination.

Authors:  C Chew; J L Halliday; M M Riley; D J Penny
Journal:  Ultrasound Obstet Gynecol       Date:  2007-06       Impact factor: 7.299

10.  Spatio-temporal image correlation (STIC): a new tool for the prenatal screening of congenital heart defects.

Authors:  F Viñals; P Poblete; A Giuliano
Journal:  Ultrasound Obstet Gynecol       Date:  2003-10       Impact factor: 7.299

View more
  1 in total

1.  Color and power Doppler combined with Fetal Intelligent Navigation Echocardiography (FINE) to evaluate the fetal heart.

Authors:  L Yeo; R Romero
Journal:  Ultrasound Obstet Gynecol       Date:  2017-08-14       Impact factor: 7.299

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.