Literature DB >> 23475135

[Secondary reconstruction of the digital A2-flexor pulley].

R Arora1, M Lutz, L Haug, P Struve, C Deml, M Gabl.   

Abstract

OBJECTIVE: Secondary reconstruction of A2 flexor pulley for after closed rupture. INDICATIONS: Persisting impairment of finger function and strength after combined injury of A2 and C1 pulley. Passive free movement of all finger joints. CONTRAINDICATIONS: Fixed flexion contractures of interphalangeal joints after complex finger injuries. Degenerative arthrosis of interphalangeal joints. SURGICAL TECHNIQUE: A strip of extensor retinaculum approximately 10 mm in width together with the periosteum from the second floor of the extensor tunnel was used for reconstruction of the A2 pulley. After drilling bilateral burr holes in the palmar aspect of the phalanx at the distal and proximal ends of the A2 pulley, the graft was fixed by the periosteum to the bone of the phalanx, placing the synovial layer innermost. POSTOPERATIVE MANAGEMENT: Postoperatively, patients in both treatment groups wore a palmar splint which extended from the distal interphalangeal joint to the proximal palmar crease for 4 weeks. The metacarpophalangeal joint and the proximal interphalangeal joint were held in full extension. After removing the splint, physiotherapy was started. Full load-bearing, hard manual work and sport activities were not permitted for 3 months.
RESULTS: Fifteen patients were treated using the extensor retinaculum for reconstruction of the A2 flexor pulley. The mean follow-up time was 48 months. The average range of motion of the PIP joint was 97 %, the average power grip strength 96 %, the finger pinch strength 100 %, and the average circumference 95 % of the uninjured contralateral side. The Buck-Gramcko score showed the following results: 10 excellent, 2 good, and 1 fair.

Entities:  

Mesh:

Year:  2013        PMID: 23475135     DOI: 10.1007/s00064-011-0053-7

Source DB:  PubMed          Journal:  Oper Orthop Traumatol        ISSN: 0934-6694            Impact factor:   1.154


  10 in total

1.  The use of a graft from the second extensor compartment to reconstruct the A2 flexor pulley in the long finger.

Authors:  M Gabl; C Reinhart; M Lutz; G Bodner; P Angermann; S Pechlaner
Journal:  J Hand Surg Br       Date:  2000-02

2.  Finger pulley injuries in extreme rock climbers: depiction with dynamic US.

Authors:  Andrea Klauser; Ferdinand Frauscher; Gerd Bodner; Ethan J Halpern; Michael F Schocke; Peter Springer; Markus Gabl; Werner Judmaier; Dieter zur Nedden
Journal:  Radiology       Date:  2002-03       Impact factor: 11.105

3.  Flexor tendon-pulley interaction after pulley reconstruction: a biomechanical study in a human model in vitro.

Authors:  J Nishida; P C Amadio; P C Bettinger; K N An
Journal:  J Hand Surg Am       Date:  1998-07       Impact factor: 2.230

4.  A mechanical study of six digital pulley reconstruction techniques: Part I. Mechanical effectiveness.

Authors:  C J Widstrom; G Johnson; J R Doyle; P R Manske; P Inhofe
Journal:  J Hand Surg Am       Date:  1989-09       Impact factor: 2.230

5.  Digital pulley reconstruction employing the always present rim of the previous pulley.

Authors:  H E Klinert; J B Bennett
Journal:  J Hand Surg Am       Date:  1978-05       Impact factor: 2.230

6.  Closed traumatic rupture of finger flexor pulleys.

Authors:  W H Bowers; G R Kuzma; D K Bynum
Journal:  J Hand Surg Am       Date:  1994-09       Impact factor: 2.230

7.  The "belt loop" technique for the reconstruction of pulleys in the first stage of flexor tendon grafting.

Authors:  A Karev
Journal:  J Hand Surg Am       Date:  1984-11       Impact factor: 2.230

8.  Reconstruction of pulleys employing extensor retinaculum.

Authors:  G D Lister
Journal:  J Hand Surg Am       Date:  1979-09       Impact factor: 2.230

9.  Anatomy of the flexor tendon sheath and pulley system: a current review.

Authors:  J R Doyle
Journal:  J Hand Surg Am       Date:  1989-03       Impact factor: 2.230

10.  Diagnosis of digital flexor tendon annular pulley disruption: comparison of high frequency ultrasound and MRI.

Authors:  G Bodner; A Rudisch; M Gabl; W Judmaier; P Springer; A Klauser
Journal:  Ultraschall Med       Date:  1999-08       Impact factor: 6.548

  10 in total
  1 in total

Review 1.  [Pulley reconstruction in the hand].

Authors:  M F Langer; S Oeckenpöhler; R Hartensuer; K Herrmann; B Wieskötter
Journal:  Orthopade       Date:  2015-10       Impact factor: 1.087

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.