A 6-fr guiding catheter (slim guide(®)) for use with multiple microdevices. An experimental study.

Y Kai1, Y Ohmori, M Watanabe, Y Kaku, M Morioka, T Hirano, S Yano, T Kawano, J-I Hamada, J-I Kuratsu.   

Abstract

A modified technique is required in patients with wide-necked aneurysms whose treatment by the single microcatheter technique is difficult. We developed a 6-Fr guiding catheter (Slim Guide(®)) that features a large lumen (0.072 inch) for performing the modified technique. To evaluate the usefulness of Slim Guide(®) we carried out experiments using three types of 6-Fr guiding catheter. In experiment 1, the shaft hardness and kink resistance were compared among three different guiding catheters (Slim Guide(®), Launcher(®), Envoy(®)). In experiment 2, we inserted a microballoon catheter and a microcatheter into the three different guiding catheters and recorded the maximal infusion pressure. In experiment 3, we inserted 13 different types of microdevices into the three different guiding catheters and evaluated the resistance of the microdevices. Although the shaft of the Slim Guide(®) was softer than that of the other two guiding catheters, its kink resistance was comparable. The maximal infusion pressure was significantly lower than with Launcher(®) or Envoy(®) catheters. Furthermore, with Slim Guide(®), in 136 of 143 microdevice combinations examined (95.1%) there was no resistance; this was true for 125 (87.4%) and 116 (81.1%) combinations using the Launcher(®) - and the Envoy(®) guiding catheters, respectively. There was a significant difference between Slim Guide(®) and the other two guiding catheters with respect to their accommodation of double microsystems (p<0.05). Although the inner diameter of Slim Guide(®) is slightly larger than of the other two guiding catheters, it significantly increased the combination of microdevices that could be used for the coil embolization of difficult aneurysms.

Entities:  

Mesh:

Year:  2013        PMID: 23472717      PMCID: PMC3601621          DOI: 10.1177/159101991301900101

Source DB:  PubMed          Journal:  Interv Neuroradiol        ISSN: 1591-0199            Impact factor:   1.610


  15 in total

1.  Balloon-assist technique for endovascular coil embolization of geometrically difficult intracranial aneurysms.

Authors:  A M Malek; V V Halbach; C C Phatouros; T E Lempert; P M Meyers; C F Dowd; R T Higashida
Journal:  Neurosurgery       Date:  2000-06       Impact factor: 4.654

2.  Double microcatheter technique for endovascular coiling of wide-neck aneurysms using a new guiding device for the transcarotid approach: technical note.

Authors:  Yutaka Kai; Jun-ichiro Hamada; Motohiro Morioka; Shigetoshi Yano; Takamasa Mizuno; Jun-ichi Kuratsu
Journal:  Neuroradiology       Date:  2005-01-13       Impact factor: 2.804

3.  Balloon-assisted coiling through a single 6F guiding catheter.

Authors:  G D Luzardo; I B Ross; G Gal
Journal:  AJNR Am J Neuroradiol       Date:  2006-01       Impact factor: 3.825

4.  Temporary balloon protection as an adjunct to endosaccular coiling of wide-necked cerebral aneurysms: technical note.

Authors:  R A Mericle; A K Wakhloo; R Rodriguez; L R Guterman; L N Hopkins
Journal:  Neurosurgery       Date:  1997-10       Impact factor: 4.654

5.  The "Remodelling Technique" in the Treatment of Wide Neck Intracranial Aneurysms. Angiographic Results and Clinical Follow-up in 56 Cases.

Authors:  J Moret; C Cognard; A Weill; L Castaings; A Rey
Journal:  Interv Neuroradiol       Date:  2001-05-15       Impact factor: 1.610

6.  Ballonn-assisted Guglielmi detachable coiling of wide-necked aneurysma: Part II--clinical results.

Authors:  M A Lefkowitz; Y P Gobin; Y Akiba; G R Duckwiler; Y Murayama; G Guglielmi; N A Martin; F Viñuela
Journal:  Neurosurgery       Date:  1999-09       Impact factor: 4.654

7.  Embolization of wide-necked aneurysms with using three or more microcatheters.

Authors:  O-K Kwon; S H Kim; C W Oh; M H Han; H-S Kang; B J Kwon; J H Kim; D H Han
Journal:  Acta Neurochir (Wien)       Date:  2006-09-29       Impact factor: 2.216

8.  Balloon-assisted coil placement in wide-necked aneurysms. Technical note.

Authors:  D I Levy; A Ku
Journal:  J Neurosurg       Date:  1997-04       Impact factor: 5.115

9.  Endovascular treatment of posterior circulation aneurysms by electrothrombosis using electrically detachable coils.

Authors:  G Guglielmi; F Viñuela; G Duckwiler; J Dion; P Lylyk; A Berenstein; C Strother; V Graves; V Halbach; D Nichols
Journal:  J Neurosurg       Date:  1992-10       Impact factor: 5.115

10.  Double microcatheter technique for detachable coil treatment of large, wide-necked intracranial aneurysms.

Authors:  B W Baxter; D Rosso; S P Lownie
Journal:  AJNR Am J Neuroradiol       Date:  1998 Jun-Jul       Impact factor: 3.825

View more
  1 in total

1.  Strategy for endovascular coil embolization of a penetrating vertebral artery injury.

Authors:  Hiroki Uchikawa; Yutaka Kai; Yuki Ohmori; Jun-Ichi Kuratsu
Journal:  Surg Neurol Int       Date:  2015-07-08
  1 in total