Suitability of a tumour-mimicking material for the evaluation of high-intensity focused ultrasound ablation under magnetic resonance guidance.

S Pichardo1, J Kivinen, D Melodelima, L Curiel.   

Abstract

This study tests the suitability of a tumour-mimic for targeting magnetic resonance (MR)-guided high-intensity focused ultrasound (HIFU). An agarose-based tumour-mimic was injected as a warm solution that polymerized in tissue. Thermal characteristics and acoustic absorption of the mimic were observed within the values reported for tissues. The relaxation times at 3T were 1679 ± 15 ms for T1 and 41 ± 1 ms for T2. The mimic was clearly visible on in vivo images. With lower contrast the tumour-mimic was visible on T2-weighted images, where it was possible to detect the ablated tissue surrounding the mimic after sonications. HIFU sonications were performed to induce thermal ablation on and around the mimic using a Sonalleve system (Philips). MR thermometry maps were performed during HIFU. The average temperature when the sonication was done at the tumour-mimic was 67.6 ± 8.0 °C in vitro and 67.6 ± 5.0 °C in vivo. The average temperature for sonications at tissues was 68.4 ± 8.7 °C in vitro (liver) and 66.0 ± 2.6 °C in vivo (muscle), with no significant difference between tissue and tumour-mimic (p > 0.05). The tumour-mimic behaviour when using MR-guided HIFU was similar to tissues, showing that this mimic can be used as an alternative to tumour models for validating MR-guided HIFU devices targeting.

Entities:  

Mesh:

Year:  2013        PMID: 23470524     DOI: 10.1088/0031-9155/58/7/2163

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  In vivo monitoring of rat brain endocannabinoids using solid-phase microextraction.

Authors:  Momna Aslam; Carlos Feleder; Ryan J Newsom; Serge Campeau; Florin Marcel Musteata
Journal:  Bioanalysis       Date:  2019-09-05       Impact factor: 2.681

2.  MR relaxation times of agar-based tissue-mimicking phantoms.

Authors:  Anastasia Antoniou; Leonidas Georgiou; Theodora Christodoulou; Natalie Panayiotou; Cleanthis Ioannides; Nikolaos Zamboglou; Christakis Damianou
Journal:  J Appl Clin Med Phys       Date:  2022-04-12       Impact factor: 2.243

3.  An experimental model to investigate the targeting accuracy of MR-guided focused ultrasound ablation in liver.

Authors:  Lorena Petrusca; Magalie Viallon; Romain Breguet; Sylvain Terraz; Gibran Manasseh; Vincent Auboiroux; Thomas Goget; Loredana Baboi; Patrick Gross; K Michael Sekins; Christoph D Becker; Rares Salomir
Journal:  J Transl Med       Date:  2014-01-16       Impact factor: 5.531

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.