Literature DB >> 23469526

[Computer simulation study on physiological feedback parameters during chest compression].

Guang Zhang1, Jiewen Zheng, Peng Zhao, Yuxiao Wang, Shaowen Qian, Hengzhi Lu, Taihu Wu.   

Abstract

To have a thorough understanding of the CPR quality based on patients' various physiological states, the doctors must do something to simulate the chest compression physiological feedback parameters (CCPFP). The CCPFP simulation plays an important role in raising efficiency of CPR training and improving chest compression quality. In this study, the CCPFP, including cardiac output (CO), coronary perfusion pressure (CPP), partial pressure of End-tidal CO2 (PETCO2) and mean arterial relaxation pressure (MARP), was simulated using Charles F. Babbs' Model. Simulation results showed that the effect of compression depth upon CCPFP was important in the range of 2-6 cm, whereas compression rate had little effect on the CCPFP higher than 100/min; the thoracic factor is inversely proportional to the CCPFP with fixed compression depth and compression rate. The CCPFP simulation can be implemented at the various physiological statuses, and verified well with the animal experimental results and the clinical results.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23469526

Source DB:  PubMed          Journal:  Sheng Wu Yi Xue Gong Cheng Xue Za Zhi        ISSN: 1001-5515


  1 in total

1.  Closed-loop controller for chest compressions based on coronary perfusion pressure: a computer simulation study.

Authors:  Chunfei Wang; Guang Zhang; Taihu Wu; Ningbo Zhan; Yaling Wang
Journal:  Med Biol Eng Comput       Date:  2015-07-04       Impact factor: 2.602

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.