Literature DB >> 23466242

Intraoperative near infrared fluorescence guided identification of the ureters using low dose methylene blue: a first in human experience.

Floris P R Verbeek1, Joost R van der Vorst, Boudewijn E Schaafsma, Rutger-Jan Swijnenburg, Katja N Gaarenstroom, Henk W Elzevier, Cornelis J H van de Velde, John V Frangioni, Alexander L Vahrmeijer.   

Abstract

PURPOSE: Near infrared fluorescence imaging is a promising technique that offers real-time visual information during surgery. In this study we report the first clinical results to our knowledge of ureteral imaging using near infrared fluorescence after a simple peripheral infusion of methylene blue. Furthermore, we assessed the optimal timing and dose of methylene blue.
MATERIALS AND METHODS: A total of 12 patients who underwent lower abdominal surgery were included in this prospective feasibility study. Near infrared fluorescence imaging was performed using the Mini-FLARE™ imaging system. To determine optimal timing and dose, methylene blue was injected intravenously at doses of 0.25, 0.5 or 1 mg/kg after exposure of the ureters. Imaging was performed for up to 60 minutes after injection.
RESULTS: In all patients both ureters could be clearly visualized within 10 minutes after infusion of methylene blue. The signal lasted at least up to 60 minutes after injection. The mean signal-to-background ratio of the ureter was 2.27 ± 1.22 (4), 2.61 ± 1.88 (4) and 3.58 ± 3.36 (4) for the 0.25, 0.5 and 1 mg/kg groups, respectively. A mixed model analysis was used to compare signal-to-background ratios among dose groups and times, and to assess the relationship between dose and time. A significant difference among time points (p <0.001) was found. However, no difference was observed among dose groups (p = 0.811).
CONCLUSIONS: This study demonstrates the first successful use of near infrared fluorescence using low dose methylene blue for the identification of the ureters during lower abdominal surgery.
Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  BMI; MB; NIR; SBR; body mass index; fluorescence; methylene blue; molecular imaging; near infrared; signal-to-background ratio; ureter; urology

Mesh:

Substances:

Year:  2013        PMID: 23466242      PMCID: PMC3686854          DOI: 10.1016/j.juro.2013.02.3187

Source DB:  PubMed          Journal:  J Urol        ISSN: 0022-5347            Impact factor:   7.450


  26 in total

Review 1.  Optical diagnostics in urology: current applications and future prospects.

Authors:  P Crow; N Stone; C A Kendall; R A Persad; M P J Wright
Journal:  BJU Int       Date:  2003-09       Impact factor: 5.588

Review 2.  Image-guided surgery using invisible near-infrared light: fundamentals of clinical translation.

Authors:  Sylvain Gioux; Hak Soo Choi; John V Frangioni
Journal:  Mol Imaging       Date:  2010-10       Impact factor: 4.488

Review 3.  The clinical use of indocyanine green as a near-infrared fluorescent contrast agent for image-guided oncologic surgery.

Authors:  Boudewijn E Schaafsma; J Sven D Mieog; Merlijn Hutteman; Joost R van der Vorst; Peter J K Kuppen; Clemens W G M Löwik; John V Frangioni; Cornelis J H van de Velde; Alexander L Vahrmeijer
Journal:  J Surg Oncol       Date:  2011-04-14       Impact factor: 3.454

4.  Urinary tract injuries: recognition and management.

Authors:  Scott E Delacroix; J C Winters
Journal:  Clin Colon Rectal Surg       Date:  2010-09

5.  Visualisation of the lymph node pathway in real time by laparoscopic radioisotope- and fluorescence-guided sentinel lymph node dissection in prostate cancer staging.

Authors:  Stephan Jeschke; Lukas Lusuardi; Andy Myatt; Stephan Hruby; Christian Pirich; Guenter Janetschek
Journal:  Urology       Date:  2012-09-15       Impact factor: 2.649

6.  Intraoperative laparoscopic fluorescence guidance to the sentinel lymph node in prostate cancer patients: clinical proof of concept of an integrated functional imaging approach using a multimodal tracer.

Authors:  Henk G van der Poel; Tessa Buckle; Oscar R Brouwer; Renato A Valdés Olmos; Fijs W B van Leeuwen
Journal:  Eur Urol       Date:  2011-04-01       Impact factor: 20.096

7.  Iatrogenic ureteral injuries: a 20-year experience in treating 165 injuries.

Authors:  A A Selzman; J P Spirnak
Journal:  J Urol       Date:  1996-03       Impact factor: 7.450

8.  Sentinel lymph node mapping of invasive urinary bladder cancer in animal models using invisible light.

Authors:  Deborah W Knapp; Larry G Adams; Alec M Degrand; Jacqueline D Niles; José A Ramos-Vara; Ann B Weil; Michael A O'Donnell; Michael D Lucroy; John V Frangioni
Journal:  Eur Urol       Date:  2007-07-16       Impact factor: 20.096

9.  The implications of lighted ureteral stenting in laparoscopic colectomy.

Authors:  Fadi Chahin; Amit J Dwivedi; Anil Paramesh; Wai Chau; Sunita Agrawal; Chadi Chahin; Anil Kumar; A Tootla; Farooq Tootla; Yvan J Silva
Journal:  JSLS       Date:  2002 Jan-Mar       Impact factor: 2.172

Review 10.  Optical image-guided surgery--where do we stand?

Authors:  Stijn Keereweer; Jeroen D F Kerrebijn; Pieter B A A van Driel; Bangwen Xie; Eric L Kaijzel; Thomas J A Snoeks; Ivo Que; Merlijn Hutteman; Joost R van der Vorst; J Sven D Mieog; Alexander L Vahrmeijer; Cornelis J H van de Velde; Robert J Baatenburg de Jong; Clemens W G M Löwik
Journal:  Mol Imaging Biol       Date:  2011-04       Impact factor: 3.488

View more
  39 in total

1.  Optimization of liposomal indocyanine green for imaging of the urinary pathways and a proof of concept in a pig model.

Authors:  Yael Friedman-Levi; Liraz Larush; Michele Diana; Francesco Marchegiani; Jacques Marescaux; Noam Goder; Guy Lahat; Joseph Klausner; Sara Eyal; Shlomo Magdassi; Eran Nizri
Journal:  Surg Endosc       Date:  2017-08-04       Impact factor: 4.584

2.  [Development of a near-infrared fluorescence imaging system based on fluorescence properties of methylene blue].

Authors:  Lu-Mao Huang; Pei-Yan DU; Lan Chen; Sa Zhang; Di-Fu Zhou; Chun-Lin Chen; Xue-Gang Xin
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2018-04-20

3.  Design and characterization of an optimized simultaneous color and near-infrared fluorescence rigid endoscopic imaging system.

Authors:  Vivek Venugopal; Minho Park; Yoshitomo Ashitate; Florin Neacsu; Frank Kettenring; John V Frangioni; Sidhu P Gangadharan; Sylvain Gioux
Journal:  J Biomed Opt       Date:  2013-12       Impact factor: 3.170

Review 4.  Image-guided cancer surgery using near-infrared fluorescence.

Authors:  Alexander L Vahrmeijer; Merlijn Hutteman; Joost R van der Vorst; Cornelis J H van de Velde; John V Frangioni
Journal:  Nat Rev Clin Oncol       Date:  2013-07-23       Impact factor: 66.675

Review 5.  NIR fluorescent small molecules for intraoperative imaging.

Authors:  Eric A Owens; Stephanie Lee; JungMun Choi; Maged Henary; Hak Soo Choi
Journal:  Wiley Interdiscip Rev Nanomed Nanobiotechnol       Date:  2015-01-30

Review 6.  Near-infrared fluorescence imaging for real-time intraoperative anatomical guidance in minimally invasive surgery: a systematic review of the literature.

Authors:  Rutger M Schols; Niels J Connell; Laurents P S Stassen
Journal:  World J Surg       Date:  2015-05       Impact factor: 3.352

7.  Optimization of fluorescent imaging in the operating room through pulsed acquisition and gating to ambient background cycling.

Authors:  Kristian J Sexton; Yan Zhao; Scott C Davis; Shudong Jiang; Brian W Pogue
Journal:  Biomed Opt Express       Date:  2017-04-26       Impact factor: 3.732

8.  An Augmented Reality Endoscope System for Ureter Position Detection.

Authors:  Feng Yu; Enmin Song; Hong Liu; Yunlong Li; Jun Zhu; Chih-Cheng Hung
Journal:  J Med Syst       Date:  2018-06-25       Impact factor: 4.460

Review 9.  Fluorescence Guidance in Surgical Oncology: Challenges, Opportunities, and Translation.

Authors:  Madeline T Olson; Quan P Ly; Aaron M Mohs
Journal:  Mol Imaging Biol       Date:  2019-04       Impact factor: 3.488

10.  Comparison of a chimeric anti-carcinoembryonic antigen antibody conjugated with visible or near-infrared fluorescent dyes for imaging pancreatic cancer in orthotopic nude mouse models.

Authors:  Ali A Maawy; Yukihiko Hiroshima; Sharmeela Kaushal; George A Luiken; Robert M Hoffman; Michael Bouvet
Journal:  J Biomed Opt       Date:  2013-12       Impact factor: 3.170

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.