Literature DB >> 23465819

Three-dimensional power Doppler study of endometrial and subendometrial microvascularization in women with intrauterine device-induced menorrhagia.

Akmal El-Mazny1, Nermeen Abou-Salem, Hossam Elshenoufy.   

Abstract

OBJECTIVE: To evaluate endometrial and subendometrial microvascularization, using three-dimensional (3D) power Doppler ultrasound, in women with intrauterine device (IUD)-induced menorrhagia; and whether those potential findings could predict the risk of bleeding before IUD insertion.
DESIGN: Prospective clinical trial.
SETTING: University teaching hospital. PATIENT(S): One hundred twenty women, who requested the insertion of a copper IUD for contraception. INTERVENTION(S): Endometrial thickness and volume, uterine artery pulsatility index and resistance index, and endometrial and subendometrial 3D power Doppler vascularization index, flow index, and vascularization flow index were measured twice: immediately before and 3 months after IUD insertion. MAIN OUTCOME MEASURE(S): Doppler indices before and after IUD insertion. RESULT(S): Before IUD insertion, no significant difference was detected in the clinical characteristics, endometrial thickness and volume, and Doppler indices between women who had IUD-induced menorrhagia (n = 47) and those without menorrhagia (n = 73). However, after IUD insertion, there was a significant increase in the endometrial and subendometrial vascularization index, flow index, and vascularization flow index in women with menorrhagia, whereas other parameters remained not significantly different between the two groups. CONCLUSION(S): Endometrial and subendometrial microvascularization increases in women with IUD-induced menorrhagia; however, this finding has no predictive value before IUD insertion.
Copyright © 2013 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23465819     DOI: 10.1016/j.fertnstert.2013.01.151

Source DB:  PubMed          Journal:  Fertil Steril        ISSN: 0015-0282            Impact factor:   7.329


  1 in total

1.  Different bleeding patterns with the use of levonorgestrel intrauterine system: are they associated with changes in uterine artery blood flow?

Authors:  Carlo Bastianelli; Manuela Farris; Stefania Rapiti; Roberta Bruno Vecchio; Giuseppe Benagiano
Journal:  Biomed Res Int       Date:  2014-04-23       Impact factor: 3.411

  1 in total