Literature DB >> 23464950

Columbus navigated TKA system: clinical and radiological results at a minimum of 5 years with survivorship analysis.

Sam Hakki1, Khaled J Saleh, Anish G Potty, Victor Bilotta, Daniel Oliveira.   

Abstract

The major factors that determine a favorable long-term clinical and functional outcome after conventional total knee arthroplasty (TKA) include correct implant positioning and restoration of the mechanical axis with soft tissue balancing to reduce aseptic failure; hence, the need for further developmental strategies that improve the accuracy and reproducibility of the surgical technique remains paramount for contemporary navigation research. Not all navigation systems are the same. The literature published thus far on mid-term results of navigated TKA relies on software that has no step-by-step soft tissue balancing with the tibia-first technique. The results are equivalent to those of conventional TKA.Therefore, the current authors conducted a minimum 5-year follow-up of a soft tissue-based navigated TKA system with the goal of soft tissue balancing. They analyzed intraoperative alignment and range of motion measurements, functional outcomes, radiographic assessment, and survival rates of high-flexion, high-conformity unresurfaced patella TKAs. The results at 5 years revealed a component revision rate of 0% compared with other nonnavigated TKAs (2.8% revision rate). The authors achieved a well-balanced TKA with a 0°±2° mechanical axis and an improved range of motion from 95° preoperatively to 110° postoperatively. Copyright 2013, SLACK Incorporated.

Entities:  

Mesh:

Year:  2013        PMID: 23464950     DOI: 10.3928/01477447-20130222-19

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  7 in total

1.  [5-year follow-up of 210 Columbus knee prostheses : A prospective multicentre study].

Authors:  Andreas Fuchs; Philip Häussermann; Dirk Hömig; Björn Gunnar Ochs; Christof A Müller; Peter Helwig; Lukas Konstantinidis
Journal:  Orthopade       Date:  2018-10       Impact factor: 1.087

2.  Comparison of ultra-congruent mobile- and fixed-bearing navigation-assisted total knee arthroplasty with minimum 5-year follow-up.

Authors:  Seong Hwan Kim; Jung-Won Lim; Young-Bong Ko; Min-Gu Song; Han-Jun Lee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2016-05-04       Impact factor: 4.342

3.  Unsatisfactory clinical outcomes of second-generation mobile bearing floating platform total knee arthroplasty: comparing outcomes with fixed bearing after five years minimum.

Authors:  Jung-Ro Yoon; Jae-Hyuk Yang
Journal:  Int Orthop       Date:  2018-03-20       Impact factor: 3.075

4.  No differences in clinical outcomes between fixed- and mobile-bearing computer-assisted total knee arthroplasties and no correlations between navigation data and clinical scores.

Authors:  Carlos J Marques; Sandra Daniel; Anusch Sufi-Siavach; Frank Lampe
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-06-15       Impact factor: 4.342

5.  Midterm survivorship and clinical outcome of INDUS knee prosthesis: 5 year followup study.

Authors:  Kantilal H Sancheti; Parag K Sancheti; Rajeev S Joshi; Kailash R Patil; Ashok K Shyam; Raja R Bhaskar
Journal:  Indian J Orthop       Date:  2016 Mar-Apr       Impact factor: 1.251

6.  10-year follow-up of the Columbus knee prostheses system in a prospective multicenter study.

Authors:  Andreas Fuchs; Philip Häussermann; Dirk Hömig; Björn Gunnar Ochs; Tim Klopfer; Christof A Müller; Peter Helwig; Lukas Konstantinidis
Journal:  Arch Orthop Trauma Surg       Date:  2021-09-09       Impact factor: 2.928

Review 7.  A Systematic Literature Review of Three Modalities in Technologically Assisted TKA.

Authors:  William A Leone; Leah C Elson; Christopher R Anderson
Journal:  Adv Orthop       Date:  2015-11-18