A three-dimensional finite element model of round window membrane vibration before and after stapedotomy surgery.

Monika Kwacz1, Piotr Marek, Paweł Borkowski, Maciej Mrówka.   

Abstract

Piston stapes prostheses are implanted in patients with refractory conductive or mixed hearing loss due to stapes otosclerosis to stimulate the perilymph with varying degrees of success. The overclosure effect described by the majority of researchers affects mainly low and medium frequencies, and a large number of patients report a lack of satisfactory results for frequencies above 2 kHz. The mechanics of perilymph stimulation with the piston have not been studied in a systematic manner. The objective of this study was to assess the influence of stapedotomy surgery on round window membrane vibration and to estimate the postoperative outcomes using the finite element (FE) method. The study hypothesis is that the three-dimensional FE model developed of the human inner ear, which simulates the round window (RW) membrane vibration, can be used to assess the influence of stapedotomy on auditory outcomes achieved after the surgical procedure. An additional objective of the study was to enable the simulation of RW membrane vibration after stapedotomy using a new type of stapes prosthesis currently under investigation at Warsaw University of Technology. A three-dimensional finite element (FE) model of the human inner ear was developed and validated using experimental data. The model was then used to simulate the round window membrane vibration before and after stapedotomy surgery. Functional alterations of the RW membrane vibration were derived from the model and compared with the results of experimental measurements from temporal bones of a human cadaver. Piston stapes prosthesis implantation causes an approximately fivefold (14 dB) lower amplitude of the RW membrane vibrations compared with normal anatomical conditions. A satisfactory agreement between the FE model and the experimental data was found. The new prosthesis caused an increase of 20-30 dB in the RW displacement amplitude compared with the 0.4-mm piston prosthesis. In all frequencies, the FE model predicted a RW displacement curve that was above the experimental curves for the normal ear. The stapedotomy can be well simulated by the FE model to predict the auditory outcomes achieved following this otosurgery procedure. The 3D FE model developed in this study may be used to optimize the geometry of a new type of stapes prosthesis in order to achieve a similar sound transmission through the inner ear as for a normal middle ear. This should provide better auditory outcomes for patients with stapedial otosclerosis.

Entities:  

Mesh:

Year:  2013        PMID: 23462937      PMCID: PMC3824605          DOI: 10.1007/s10237-013-0479-y

Source DB:  PubMed          Journal:  Biomech Model Mechanobiol        ISSN: 1617-7940


  80 in total

1.  Three-dimensional stapes footplate motion in human temporal bones.

Authors:  Naohito Hato; Stefan Stenfelt; Richard L Goode
Journal:  Audiol Neurootol       Date:  2003 May-Jun       Impact factor: 1.854

2.  How can the cochlear amplifier be realized by the outer hair cells which have nothing to push against?

Authors:  Tatsuya Fukazawa
Journal:  Hear Res       Date:  2002-10       Impact factor: 3.208

3.  Computer-integrated finite element modeling of human middle ear.

Authors:  Q Sun; R Z Gan; K-H Chang; K J Dormer
Journal:  Biomech Model Mechanobiol       Date:  2002-10

4.  Complex stapes motions in human ears.

Authors:  Jae Hoon Sim; Michail Chatzimichalis; Michael Lauxmann; Christof Röösli; Albrecht Eiber; Alexander M Huber
Journal:  J Assoc Res Otolaryngol       Date:  2010-02-18

5.  Round window membrane motion with air conduction and bone conduction stimulation.

Authors:  Stefan Stenfelt; Naohito Hato; Richard L Goode
Journal:  Hear Res       Date:  2004-12       Impact factor: 3.208

6.  Acoustic-structural coupled finite element analysis for sound transmission in human ear--pressure distributions.

Authors:  Rong Z Gan; Qunli Sun; Bin Feng; Mark W Wood
Journal:  Med Eng Phys       Date:  2005-08-24       Impact factor: 2.242

7.  Finite element model of the stapes-inner ear interface.

Authors:  F Böhnke; W Arnold
Journal:  Adv Otorhinolaryngol       Date:  2007

8.  Differences in the perilymph fluid stimulation before and after experimental stapedotomy.

Authors:  Monika Kwacz; Maciej Mrówka; Jarosław Wysocki
Journal:  Acta Bioeng Biomech       Date:  2012       Impact factor: 1.073

9.  A cochlear model using feed-forward outer-hair-cell forces.

Authors:  C D Geisler; C Sang
Journal:  Hear Res       Date:  1995-06       Impact factor: 3.208

10.  Measurement of umbo vibration in human subjects--method and possible clinical applications.

Authors:  R L Goode; G Ball; S Nishihara
Journal:  Am J Otol       Date:  1993-05
View more
  6 in total

1.  Elastic Properties of the Annular Ligament of the Human Stapes--AFM Measurement.

Authors:  Monika Kwacz; Zygmunt Rymuza; Marcin Michałowski; Jarosław Wysocki
Journal:  J Assoc Res Otolaryngol       Date:  2015-06-04

2.  Human cochlear hydrodynamics: A high-resolution μCT-based finite element study.

Authors:  Annalisa De Paolis; Hirobumi Watanabe; Jeremy T Nelson; Marom Bikson; Mark Packer; Luis Cardoso
Journal:  J Biomech       Date:  2016-11-10       Impact factor: 2.712

Review 3.  Analytical and numerical modeling of the hearing system: Advances towards the assessment of hearing damage.

Authors:  Annalisa De Paolis; Marom Bikson; Jeremy T Nelson; J Alexander de Ru; Mark Packer; Luis Cardoso
Journal:  Hear Res       Date:  2017-02-02       Impact factor: 3.208

Review 4.  Design and optimization of auditory prostheses using the finite element method: a narrative review.

Authors:  Qianli Cheng; Han Yu; Junpei Liu; Qi Zheng; Yanru Bai; Guangjian Ni
Journal:  Ann Transl Med       Date:  2022-06

5.  A clinically oriented introduction and review on finite element models of the human cochlea.

Authors:  Dimitrios Kikidis; Athanasios Bibas
Journal:  Biomed Res Int       Date:  2014-11-04       Impact factor: 3.411

6.  New chamber stapes prosthesis - A preliminary assessment of the functioning of the prototype.

Authors:  Monika Kwacz; Magdalena Sołyga; Maciej Mrówka; Konrad Kamieniecki
Journal:  PLoS One       Date:  2017-05-23       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.