Literature DB >> 23461271

Survey of methods used to detect bacterial contamination of platelet products in the United States in 2011.

Mark E Brecher1, Michael R Jacobs, Louis M Katz, Jessica Jacobson, Jacqlyn Riposo, Allene Carr-Greer, Steve Kleinman.   

Abstract

BACKGROUND: Testing of platelets (PLTs) for bacterial contamination is required by the AABB Standards but is not fully standardized. On January 31, 2011, a new AABB Standard, 5.1.5.1.1, specified that bacterial detection methods for PLT components shall use assays either approved by the Food and Drug Administration (FDA) or validated to provide sensitivity equivalent to these FDA-approved methods.
METHODS: An Internet-based survey of AABB member institutions was conducted from May to June 2012, to document current practices used in 2011 for bacterial detection in different PLT products and to assess the impact of the new standard.
RESULTS: Of 1053 AABB member institutions surveyed, 40 of 99 blood centers (40.4%) and 184 of 954 hospital blood banks or transfusion services (19.3%) responded. Sixty-four respondents manufactured PLTs. Apheresis PLTs (APs) were predominantly screened with the BacT/ALERT system (89.5%); the majority (95.2%) were cultured with at least 8 mL of product. There was substantial variation in the minimum incubation time of cultures before release of PLTs (range, 0 to >24 hr). Recalls of released AP for possible bacterial contamination were largely successful (67.3%); successful interdiction before transfusion was associated with incubation for more than 12 hours before release (p < 0.01). After Standard 5.1.5.1.1 took effect, there was a decrease in production of whole blood-derived PLT concentrates (WBPCs). Point-of-issue ("rapid") immunoassays were used to screen a substantial proportion of WBPC PLTs, but were rarely used as secondary tests for previously cultured APs.
CONCLUSION: The survey identified variability in culture methods and release times with AP, while use of WBPC decreased after AABB Standard 5.1.5.1.1 became effective.
© 2013 American Association of Blood Banks.

Entities:  

Mesh:

Year:  2013        PMID: 23461271     DOI: 10.1111/trf.12148

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  6 in total

1.  Rapid, sensitive detection of bacteria in platelet samples with Fountain Flow Cytometry.

Authors:  Paul Johnson; Mika Moriwaki; Joseph Johnson
Journal:  J Clin Lab Anal       Date:  2017-02-08       Impact factor: 2.352

2.  Periodontitis increases risk of viable bacteria in freshly drawn blood donations.

Authors:  Christian Damgaard; Susanne G Sækmose; Martin Nilsson; Mogens Kilian; Claus H Nielsen; Palle Holmstrup
Journal:  Blood Transfus       Date:  2021-02-02       Impact factor: 3.443

3.  Viable bacteria associated with red blood cells and plasma in freshly drawn blood donations.

Authors:  Christian Damgaard; Karin Magnussen; Christian Enevold; Martin Nilsson; Tim Tolker-Nielsen; Palle Holmstrup; Claus Henrik Nielsen
Journal:  PLoS One       Date:  2015-03-09       Impact factor: 3.240

4.  Cost implications of implementation of pathogen-inactivated platelets.

Authors:  Jeffrey McCullough; Dennis Goldfinger; Jed Gorlin; William J Riley; Harpreet Sandhu; Christopher Stowell; Dawn Ward; Mary Clay; Shelley Pulkrabek; Vera Chrebtow; Adonis Stassinopoulos
Journal:  Transfusion       Date:  2015-05-18       Impact factor: 3.157

5.  Blood system changes since recognition of transfusion-associated AIDS.

Authors:  Jay S Epstein; Harold W Jaffe; Harvey J Alter; Harvey G Klein
Journal:  Transfusion       Date:  2013-08-27       Impact factor: 3.157

6.  A Fatal Case of Septic Shock Secondary to Acinetobacter Bacteremia Acquired from a Platelet Transfusion.

Authors:  C Nevala-Plagemann; P Powers; M Mir-Kasimov; R Rose
Journal:  Case Rep Med       Date:  2019-12-27
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.