| Literature DB >> 2346115 |
R K Oestenstad1, J L Perkins, V E Rose.
Abstract
A method has been developed to identify the location and shape of respirator faceseal leak sites by the deposition of a fluorescent tracer. An aerosol generation, conditioning, and exposure system to provide a test environment with stable aerosol concentration and size distribution of 4-methyl-7-diethylaminocoumarin was designed and tested. Faceseal leak sites on a respirator mounted on a mannequin and worn by human subjects were identified by deposition of the tracer aerosol and subsequent observation under long-wave ultraviolet lighting. Test parameters were identified for the optimal definition of leaks. Photographic techniques were developed to document the identified leak sites.Entities:
Mesh:
Substances:
Year: 1990 PMID: 2346115 DOI: 10.1080/15298669091369655
Source DB: PubMed Journal: Am Ind Hyg Assoc J ISSN: 0002-8894