Literature DB >> 23460385

Neointimal tissue component assessed by tissue characterization with 40 MHz intravascular ultrasound imaging: comparison of drug-eluting stents and bare-metal stents.

Kenichi Tsujita1, Naoko Takaoka, Koichi Kaikita, Seiji Hokimoto, Eiji Horio, Koji Sato, Michio Mizobe, Naoki Nakayama, Sunao Kojima, Shinji Tayama, Seigo Sugiyama, Sunao Nakamura, Hisao Ogawa.   

Abstract

OBJECTIVES: The present study used iMap IVUS system to compare neointimal tissue components between DES and bare-metal stents (BMSs).
BACKGROUND: Drug-eluting stents (DESs) can cause impaired arterial healing, which constitutes the most important pathological substrate underlying late DES thrombosis. Intravascular ultrasound (IVUS)-based tissue characterization allows for the in vivo identification of neointimal tissue components. METHODS AND
RESULTS: Follow-up IVUS data after coronary stenting (9.8 ± 9.4 months from index procedures) was obtained from consecutive 61 lesions (34 in DES, 27 in BMS). The iMap tissue components (fibrotic, lipidic, necrotic, and calcified) were measured in every recorded frame and expressed as percentages of mean neointimal cross-sectional area for the stented segment. Patients' characteristics were comparable between DES and BMS. When compared with BMSs, smaller (2.9 ± 0.4 mm vs. 3.2 ± 0.4 mm, P = 0.004) and longer (34 ± 18 mm vs. 26 ± 14 mm, P = 0.03) DESs were implanted. When compared with BMS group, minimum lumen area at follow-up was significantly greater in DES group (3.9 ± 1.8 mm(2) vs. 3.1 ± 1.5 mm(2) , P < 0.04), mainly attributable to suppression of neointimal hyperplasia (1.7 ± 0.8 mm(2) vs. 3.1 ± 1.5 mm(2) , P < 0.0001). The iMap analyses showed that neointima after DES placement was composed of smaller fibrotic component (67 ± 8% vs. 78 ± 7%, P < 0.0001), larger necrotic (14 ± 4% vs. 9 ± 3%, P < 0.0001) and calcified (15 ± 6% vs. 7 ± 4%, P < 0.0001) components compared with BMS. Logistic regression analysis showed that only intra-DES neointima was a significant predictor of necrotic neointima at follow-up.
CONCLUSIONS: DES implantation would be associated with iMap-derived necrotic and less-fibrotic neointimal formation. In vivo iMap evaluation of neointimal tissue may provide useful information in detecting impaired healing after stenting.
Copyright © 2013 Wiley Periodicals, Inc.

Entities:  

Keywords:  PCI; RSTN; VASB; intravascular ultrasound; stent

Mesh:

Substances:

Year:  2013        PMID: 23460385     DOI: 10.1002/ccd.24907

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  6 in total

1.  Coronary angioscopic imaging of in-stent restenosis after biolimus-eluting coronary stent implantation.

Authors:  Shigenori Ito; Tomoaki Saeki
Journal:  J Cardiol Cases       Date:  2015-08-11

2.  Tissue characteristics of neointima in late restenosis: integrated backscatter intravascular ultrasound analysis for in-stent restenosis.

Authors:  Hirohiko Ando; Akihiro Suzuki; Shinichiro Sakurai; Soichiro Kumagai; Akiyoshi Kurita; Katsuhisa Waseda; Hiroaki Takashima; Tetsuya Amano
Journal:  Heart Vessels       Date:  2016-10-11       Impact factor: 2.037

3.  Neointimal tissue characterization after implantation of drug-eluting stents by optical coherence tomography: quantitative analysis of optical density.

Authors:  Setsu Nishino; Masashi Sakuma; Tomoaki Kanaya; Takahisa Nasuno; Michiaki Tokura; Shigeru Toyoda; Shichiro Abe; Daisuke Nakamura; Kentaro Tanaka; Guiherme F Attizzani; Hiram G Bezerra; Marco A Costa; Teruo Inoue
Journal:  Int J Cardiovasc Imaging       Date:  2019-06-19       Impact factor: 2.357

4.  Intravascular Ultrasound-based Imaging Modalities for Tissue Characterisation.

Authors:  Andrejs Erglis; Sanda Jegere; Inga Narbute
Journal:  Interv Cardiol       Date:  2014-08

5.  The wound healing response after implantation of a drug-eluting stent is impaired persistently in the long term.

Authors:  Takahisa Nasuno; Michiaki Tokura; Michiya Kageyama; Shigeru Toyoda; Masashi Sakuma; Takaaki Komatsu; Isao Taguchi; Shichiro Abe; Teruo Inoue
Journal:  Heart Vessels       Date:  2015-05-05       Impact factor: 2.037

Review 6.  Neoatherosclerosis after Drug-Eluting Stent Implantation: Roles and Mechanisms.

Authors:  Yuanyuan Cui; Yue Liu; Fuhai Zhao; Dazhuo Shi; Keji Chen
Journal:  Oxid Med Cell Longev       Date:  2016-06-30       Impact factor: 6.543

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.