Literature DB >> 23460030

Biological dosimetry assessments of a serious radiation accident in Bulgaria in 2011.

E Grégoire1, V Hadjidekova, R Hristova, G Gruel, S Roch-Lefevre, P Voisin, A Staynova, S Deleva, E A Ainsbury, D C Lloyd, J F Barquinero.   

Abstract

In 2011, a serious radiation accident occurred in Stamboliyski, Bulgaria, in an industrial sterilisation facility using very-high-activity (60)Co sources. For the five persons accidentally exposed, biological dosimetry based on dicentric analysis was performed in Sofia and in Paris, where the patients were transferred for treatment. Before completing the chromosomal dose assessment, and for the most exposed person, a preliminary cytogenetic evaluation based on electronically transmitted metaphase images was made. The averaged acute whole-body dose estimates for the five patients ranged from 5.2 to 1.2 Gy, and good agreement was obtained between the two laboratories. The patients were also assessed by their prodromal responses and depressed blood cell counts over the first week. The cytogenetic dose estimates were in good accord with those derived from the blood counts, and both techniques indicated that, for the two most seriously exposed persons both techniques indicated that the initial prodromal reactions had suggested somewhat less severe exposure.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23460030     DOI: 10.1093/rpd/nct032

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  4 in total

1.  HEMODOSE: A Biodosimetry Tool Based on Multi-type Blood Cell Counts.

Authors:  Shaowen Hu; William F Blakely; Francis A Cucinotta
Journal:  Health Phys       Date:  2015-07       Impact factor: 1.316

Review 2.  Reported radiation overexposure accidents worldwide, 1980-2013: a systematic review.

Authors:  Karen Coeytaux; Eric Bey; Doran Christensen; Erik S Glassman; Becky Murdock; Christelle Doucet
Journal:  PLoS One       Date:  2015-03-19       Impact factor: 3.240

3.  Calibration curves by 60Co with low dose rate are different in terms of dose estimation - a comparative study.

Authors:  Mariana Esposito Mendes; Julyanne Conceição Goes de Mendonça; Suy Hwang; Marina Di Giorgio; Fabiana Farias de Lima; Neide Santos
Journal:  Genet Mol Biol       Date:  2020-02-17       Impact factor: 1.771

4.  Biological and internal dosimetry for radiation medicine: current status and future perspectives.

Authors:  Wanwisa Sudprasert; Oleg V Belyakov; Satoshi Tashiro
Journal:  J Radiat Res       Date:  2022-03-17       Impact factor: 2.724

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.