Robust spectral-domain optical coherence tomography speckle model and its cross-correlation coefficient analysis.

Xuan Liu1, Jessica C Ramella-Roman, Yong Huang, Yuan Guo, Jin U Kang.   

Abstract

In this study, we propose a generic speckle simulation for optical coherence tomography (OCT) signal, by convolving the point-spread function (PSF) of the OCT system with the numerically synthesized random sample field. We validate our model and use the simulation method to study the statistical properties of cross-correlation coefficients between A-scans, which have been recently applied in transverse motion analysis by our group. The results of simulation show that oversampling is essential for accurate motion tracking; exponential decay of OCT signal leads to an underestimate of motion that can be corrected; lateral heterogeneity of sample leads to an overestimate of motion for a few pixels corresponding to the structural boundary.

Entities:  

Mesh:

Year:  2013        PMID: 23456001      PMCID: PMC3615453          DOI: 10.1364/JOSAA.30.000051

Source DB:  PubMed          Journal:  J Opt Soc Am A Opt Image Sci Vis        ISSN: 1084-7529            Impact factor:   2.129


  24 in total

1.  Speckle reduction in optical coherence tomography by frequency compounding.

Authors:  Michael Pircher; Erich Gotzinger; Rainer Leitgeb; Adolf F Fercher; Christoph K Hitzenberger
Journal:  J Biomed Opt       Date:  2003-07       Impact factor: 3.170

2.  Speckle reduction in optical coherence tomography images by use of a spatially adaptive wavelet filter.

Authors:  Desmond C Adler; Tony H Ko; James G Fujimoto
Journal:  Opt Lett       Date:  2004-12-15       Impact factor: 3.776

3.  Statistics and reduction of speckle in optical coherence tomography.

Authors:  M Bashkansky; J Reintjes
Journal:  Opt Lett       Date:  2000-04-15       Impact factor: 3.776

4.  Texture analysis of speckle in optical coherence tomography images of tissue phantoms.

Authors:  Kirk W Gossage; Cynthia M Smith; Elizabeth M Kanter; Lida P Hariri; Alice L Stone; Jeffrey J Rodriguez; Stuart K Williams; Jennifer K Barton
Journal:  Phys Med Biol       Date:  2006-03-01       Impact factor: 3.609

5.  Ultrasonic texture motion analysis: theory and simulation.

Authors:  J Meunier; M Bertrand
Journal:  IEEE Trans Med Imaging       Date:  1995       Impact factor: 10.048

6.  Speckle reduction in optical coherence tomography images using digital filtering.

Authors:  Aydogan Ozcan; Alberto Bilenca; Adrien E Desjardins; Brett E Bouma; Guillermo J Tearney
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2007-07       Impact factor: 2.129

7.  Statistics of local speckle contrast.

Authors:  Donald D Duncan; Sean J Kirkpatrick; Ruikang K Wang
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2008-01       Impact factor: 2.129

8.  Speckle in optical coherence tomography.

Authors:  J M Schmitt; S H Xiang; K M Yung
Journal:  J Biomed Opt       Date:  1999-01       Impact factor: 3.170

9.  Logarithmic intensity and speckle-based motion contrast methods for human retinal vasculature visualization using swept source optical coherence tomography.

Authors:  Reza Motaghiannezam; Scott Fraser
Journal:  Biomed Opt Express       Date:  2012-02-10       Impact factor: 3.732

10.  Spectroscopic-speckle variance OCT for microvasculature detection and analysis.

Authors:  Xuan Liu; Kang Zhang; Yong Huang; Jin U Kang
Journal:  Biomed Opt Express       Date:  2011-10-04       Impact factor: 3.732

View more
  6 in total

1.  Stability in computed optical interferometric tomography (Part II): in vivo stability assessment.

Authors:  Nathan D Shemonski; Adeel Ahmad; Steven G Adie; Yuan-Zhi Liu; Fredrick A South; P Scott Carney; Stephen A Boppart
Journal:  Opt Express       Date:  2014-08-11       Impact factor: 3.894

2.  Noise adaptive wavelet thresholding for speckle noise removal in optical coherence tomography.

Authors:  Farzana Zaki; Yahui Wang; Hao Su; Xin Yuan; Xuan Liu
Journal:  Biomed Opt Express       Date:  2017-04-26       Impact factor: 3.732

3.  Economical and compact briefcase spectral-domain optical coherence tomography system for primary care and point-of-care applications.

Authors:  Roshan Dsouza; Jungeun Won; Guillermo L Monroy; Darold R Spillman; Stephen A Boppart
Journal:  J Biomed Opt       Date:  2018-09       Impact factor: 3.170

4.  Quantitative transverse flow measurement using optical coherence tomography speckle decorrelation analysis.

Authors:  Xuan Liu; Yong Huang; Jessica C Ramella-Roman; Scott A Mathews; Jin U Kang
Journal:  Opt Lett       Date:  2013-03-01       Impact factor: 3.776

5.  Assessment and removal of additive noise in a complex optical coherence tomography signal based on Doppler variation analysis.

Authors:  Xuan Liu; Farzana Zaki; Dylan Renaud
Journal:  Appl Opt       Date:  2018-04-10       Impact factor: 1.980

6.  Signal-carrying speckle in optical coherence tomography: a methodological review on biomedical applications.

Authors:  Vania B Silva; Danilo Andrade De Jesus; Stefan Klein; Theo van Walsum; João Cardoso; Luisa Sánchez Brea; Pedro G Vaz
Journal:  J Biomed Opt       Date:  2022-03       Impact factor: 3.758

  6 in total