Literature DB >> 23455169

A quantitative comparison of soft tissue compressive viscoelastic model accuracy.

Xin Wang1, Jonathan A Schoen, Mark E Rentschler.   

Abstract

Viscoelastic models are generally considered a good option for modeling biological tissue due to tissue time-dependency. However, although various forms of viscoelastic models have been developed, only a few have shown a good balance between model mathematical simplicity and experimental fit accuracy. Starting from a basic Standard Linear Solid (SLS) model, a systematic modification of the viscoelastic model leading to a more accurate tissue model is presented. A five-element model family, with a Double Maxwell-arm Wiechert (DMW) representative model, is selected for its mathematical simplicity and mathematical loading accuracy. This DMW model is then used to fit experimental data collected from stress relaxation indentation tests performed on fresh porcine liver and spleen. The results show that this DMW model provides a closer fit with the experimental liver (SLS R(2)=0.731, DMW R(2)=0.991) and spleen (SLS R(2)=0.720, DMW R(2)=0.981) data, compared to an SLS model, while maintaining appreciable mathematical simplicity by using only five model elements, compared to seven-element models. Thus, any model from this five-element model family can be used as a base compressive model for complex soft tissue with an approximate 35% improved model fit over SLS. Finally, model element parameters for in vitro fresh porcine liver and spleen are determined from the associated indentation tests.
Copyright © 2013 Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23455169     DOI: 10.1016/j.jmbbm.2013.01.007

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  3 in total

1.  Surface deformation and reaction force estimation of liver tissue based on a novel nonlinear mass-spring-damper viscoelastic model.

Authors:  Árpád Takács; Imre J Rudas; Tamás Haidegger
Journal:  Med Biol Eng Comput       Date:  2015-12-30       Impact factor: 2.602

2.  Viscoelastic characterization of the primate finger pad in vivo by microstep indentation and three-dimensional finite element models for tactile sensation studies.

Authors:  Siddarth Kumar; Gang Liu; David W Schloerb; Mandayam A Srinivasan
Journal:  J Biomech Eng       Date:  2015-03-18       Impact factor: 2.097

3.  Tissue stress from laparoscopic grasper use and bowel injury in humans: establishing intraoperative force boundaries.

Authors:  Amanda Farah Khan; Matthew Kenneth MacDonald; Catherine Streutker; Corwyn Rowsell; James Drake; Teodor Grantcharov
Journal:  BMJ Surg Interv Health Technol       Date:  2021-07-05
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.