Comparisons of fully automated syphilis tests with conventional VDRL and FTA-ABS tests.

Seung Jun Choi1, Yongjung Park, Eun Young Lee, Sinyoung Kim, Hyon-Suk Kim.   

Abstract

BACKGROUND: Serologic tests are widely used for the diagnosis of syphilis. However, conventional methods require well-trained technicians to produce reliable results. We compared automated nontreponemal and treponemal tests with conventional methods.
METHODS: The HiSens Auto Rapid Plasma Reagin (AutoRPR) and Treponema Pallidum particle agglutination (AutoTPPA) tests, which utilize latex turbidimetric immunoassay, were assessed. A total of 504 sera were assayed by AutoRPR, AutoTPPA, conventional VDRL and FTA-ABS. Among them, 250 samples were also tested by conventional TPPA.
RESULTS: The concordance rate between the results of VDRL and AutoRPR was 67.5%, and 164 discrepant cases were all VDRL reactive but AutoRPR negative. In the 164 cases, 133 showed FTA-ABS reactivity. Medical records of 106 among the 133 cases were reviewed, and 82 among 106 specimens were found to be collected from patients already treated for syphilis. The concordance rate between the results of AutoTPPA and FTA-ABS was 97.8%. The results of conventional TPPA and AutoTPPA for 250 samples were concordant in 241 cases (96.4%). AutoRPR showed higher specificity than that of VDRL, while VDRL demonstrated higher sensitivity than that of AutoRPR regardless of whether the patients had been already treated for syphilis or not. Both FTA-ABS and AutoTPPA showed high sensitivities and specificities greater than 98.0%.
CONCLUSIONS: Automated RPR and TPPA tests could be alternatives to conventional syphilis tests, and AutoRPR would be particularly suitable in treatment monitoring, since results by AutoRPR in cases after treatment became negative more rapidly than by VDRL.
Copyright © 2013. Published by Elsevier Inc.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23454393     DOI: 10.1016/j.clinbiochem.2013.02.008

Source DB:  PubMed          Journal:  Clin Biochem        ISSN: 0009-9120            Impact factor:   3.281


  8 in total

1.  Usefulness of Automated Latex Turbidimetric Rapid Plasma Reagin Test for Diagnosis and Evaluation of Treatment Response in Syphilis in Comparison with Manual Card Test: a Prospective Cohort Study.

Authors:  Motoyuki Tsuboi; Takeshi Nishijima; Takahiro Aoki; Katsuji Teruya; Yoshimi Kikuchi; Hiroyuki Gatanaga; Shinichi Oka
Journal:  J Clin Microbiol       Date:  2018-10-25       Impact factor: 5.948

2.  Comparison of Manual and Fully Automated AIX1000 Rapid Plasma Reagin Assays for Laboratory Diagnosis of Syphilis.

Authors:  Alan M Sanfilippo; Kristie Freeman; John L Schmitz
Journal:  J Clin Microbiol       Date:  2018-07-26       Impact factor: 5.948

3.  Treponemal antibody in CSF and cellular immunity in peripheral blood of syphilitic patients with persisting positive rapid plasma regain.

Authors:  Wei-Qiang He; Huan-Li Wang; Dao-Qing Zhong; Lu-Yang Lin; Xiao-Shan Qiu; Ri-Dong Yang
Journal:  Int J Clin Exp Pathol       Date:  2015-05-01

4.  Comparison of an automated rapid plasma reagin (RPR) test with the conventional RPR card test in syphilis testing.

Authors:  Jong-Han Lee; Chae Seung Lim; Min-Geol Lee; Hyon-Suk Kim
Journal:  BMJ Open       Date:  2014-12-31       Impact factor: 2.692

Review 5.  Current Perspectives on Prevention of Mother-to-Child Transmission of Syphilis.

Authors:  Eleonor G Lago
Journal:  Cureus       Date:  2016-03-09

Review 6.  Efforts in blood safety: Integrated approach for serological diagnosis of syphilis.

Authors:  Linda Sommese; Maria Rosaria De Pascale; Maria Capuano; Claudio Napoli
Journal:  Asian J Transfus Sci       Date:  2016 Jan-Jun

7.  Serologic Response to Treatment in Human Immunodeficiency Virus-Negative Syphilis Patients Using Automated Serological Tests: Proposals for New Guidelines.

Authors:  Jung-In Kim; Ji-Hye Park; Ju-Yeon Choi; Ga-Young Lee; Won-Serk Kim
Journal:  Ann Dermatol       Date:  2017-10-30       Impact factor: 1.444

8.  Urea-mediated dissociation alleviate the false-positive Treponema pallidum-specific antibodies detected by ELISA.

Authors:  Qiang Wang; Yan Lei; Xiaolan Lu; Guangrong Wang; Qin Du; Xiaolan Guo; Yan Xing; Guoyuan Zhang; Dongsheng Wang
Journal:  PLoS One       Date:  2019-03-05       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.