Literature DB >> 23453543

Inter-application variation of dose and spatial location of D(2cm(3)) volumes of OARs during MR image based cervix brachytherapy.

Swamidas V Jamema1, Umesh Mahantshetty, Kari Tanderup, Deepti Malvankar, Shilpa Sharma, Reena Engineer, Supriya Chopra, Shyam K Shrivastava, Deepak D Deshpande.   

Abstract

PURPOSE: Evaluation of Inter-application variation of doses and spatial location of D(2cm(3)) volumes of OARs during MR-image based cervix brachytherapy.
MATERIALS AND METHODS: Twenty-seven patients treated with EMBRACE protocol were analyzed. Every patient had two applications, one week apart. For each application patient had undergone MR-imaging (MR-1 and MR-2), volume delineation, reconstruction, treatment planning (plan-1 and plan-2) and dose evaluation. Both the image series were then co-registered with applicator as the reference coordinate system (Eclipse planning system v8.6.14). Inter-application dose, volume and spatial location of D(2cm(3)) variation were evaluated.
RESULTS: The largest inter-application systematic and random dose variations were observed for sigmoid as compared to rectum and bladder. The mean (±SD) of the relative D(2cm(3)) variations were 0.6(±15.1)%, 0.9(±13.1)% and 11.9(±37.5)% for rectum, bladder and sigmoid respectively. The overlap of D(2cm(3)) volumes was more than 50% in 16(59%), 8(30%) and 3(11%) patients for rectum, bladder and sigmoid, respectively.
CONCLUSION: The 2cm(3) volumes between the applications/fractions are quite stable in topography for bladder and rectum, and hence the current practice of cumulative addition of D(2cm(3)) dose is expected to be valid for bladder and rectum. For sigmoid, significant topographical changes were seen, which need further validation in a larger patient population and in multi-centric settings.
Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2013        PMID: 23453543     DOI: 10.1016/j.radonc.2013.01.011

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  17 in total

Review 1.  Radiobiological considerations in combining doses from external beam radiotherapy and brachytherapy for cervical cancer.

Authors:  Ana M Tornero-López; Damián Guirado
Journal:  Rep Pract Oncol Radiother       Date:  2018-07-02

Review 2.  In vivo dosimetry: trends and prospects for brachytherapy.

Authors:  G Kertzscher; A Rosenfeld; S Beddar; K Tanderup; J E Cygler
Journal:  Br J Radiol       Date:  2014-07-08       Impact factor: 3.039

3.  [Rectal toxicity prediction based on accurate rectal surface dose summation for cervical cancer radiotherapy].

Authors:  Jia-Wei Chen; Hai-Bin Chen; Qiang He; Yu-Liang Liao; Xin Zhen
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2017-12-20

Review 4.  Magnetic resonance image guided brachytherapy.

Authors:  Kari Tanderup; Akila N Viswanathan; Christian Kirisits; Steven J Frank
Journal:  Semin Radiat Oncol       Date:  2014-07       Impact factor: 5.934

Review 5.  Brachytherapy in India - a long road ahead.

Authors:  Susovan Banerjee; Umesh Mahantshetty; Shyamkishore Shrivastava
Journal:  J Contemp Brachytherapy       Date:  2014-10-06

Review 6.  Brachytherapy for malignancies of the vagina in the 3D era.

Authors:  Scott M Glaser; Sushil Beriwal
Journal:  J Contemp Brachytherapy       Date:  2015-09-14

Review 7.  Dose Summation Strategies for External Beam Radiation Therapy and Brachytherapy in Gynecologic Malignancy: A Review from the NRG Oncology and NCTN Medical Physics Subcommittees.

Authors:  Hayeon Kim; Yongsook C Lee; Stanley H Benedict; Brandon Dyer; Michael Price; Yi Rong; Ananth Ravi; Eric Leung; Sushil Beriwal; Mark E Bernard; Jyoti Mayadev; Jessica R L Leif; Ying Xiao
Journal:  Int J Radiat Oncol Biol Phys       Date:  2021-06-17       Impact factor: 7.038

8.  A multicentre comparison of the dosimetric impact of inter- and intra-fractional anatomical variations in fractionated cervix cancer brachytherapy.

Authors:  Nicole Nesvacil; Kari Tanderup; Taran P Hellebust; Astrid De Leeuw; Stefan Lang; Sandy Mohamed; Swamidas V Jamema; Clare Anderson; Richard Pötter; Christian Kirisits
Journal:  Radiother Oncol       Date:  2013-04-18       Impact factor: 6.280

9.  Dosimetric impacts of applicator displacements and applicator reconstruction-uncertainties on 3D image-guided brachytherapy for cervical cancer.

Authors:  Joshua Schindel; Winson Zhang; Sudershan K Bhatia; Wenqing Sun; Yusung Kim
Journal:  J Contemp Brachytherapy       Date:  2013-12-18

10.  Mapping of dose distribution from IMRT onto MRI-guided high dose rate brachytherapy using deformable image registration for cervical cancer treatments: preliminary study with commercially available software.

Authors:  Hayeon Kim; M Saiful Huq; Chris Houser; Sushil Beriwal; Dariusz Michalski
Journal:  J Contemp Brachytherapy       Date:  2014-06-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.