Novel reverse-phase ion pair-high performance liquid chromatography separation of heparin, heparan sulfate and low molecular weight-heparins disaccharides and oligosaccharides.

Fabio Galeotti1, Nicola Volpi.   

Abstract

In this study, by using tetrabutylammonium bisulfate as ion-pairing reagent, we were able to separate all the main heparin/heparan sulfate disaccharides generated by the action of heparinases along with the main Hep tetrasaccharide possessing a 3-O-sulfate group on the sulfoglucosamine unit and resistant to enzymatic action. Moreover, this novel HPLC method was able to separate and quantify uncommon disaccharides/oligosaccharides present in low molecular weight-heparins produced by chemical treatment with nitrous acid, dalteparin, or benzylation followed by alkaline hydrolysis, enoxaparin. Additionally, this procedure yields a sensitivity ∼4-times higher compared to conventional strong-anion exchange-HPLC separation. This was obtained by a common UV detector at 232 nm avoiding the use of complex procedures capable of increasing sensitivity by post-column derivatization. Finally, it is worth mentioning that disaccharide/oligosaccharide composition by HPLC and UV detection is a common analytical approach in quality control laboratories to evaluate heparins and low molecular weight-heparins structure and quality during their extraction and production. This simple HPLC approach offers high resolution and sensitivity for the rapid differentiation of pharmaceutical native heparins and derivatives and for the compositional analysis of small amounts of samples derived from biological sources at a glycosaminoglycans level of a few hundred nanogram.
Copyright © 2013 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23453462     DOI: 10.1016/j.chroma.2013.02.013

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  6 in total

1.  Analysis of 3-O-sulfo group-containing heparin tetrasaccharides in heparin by liquid chromatography-mass spectrometry.

Authors:  Guoyun Li; Bo Yang; Lingyun Li; Fuming Zhang; Changhu Xue; Robert J Linhardt
Journal:  Anal Biochem       Date:  2014-03-28       Impact factor: 3.365

2.  Analysis of glycosaminoglycan-derived, precolumn, 2-aminoacridone-labeled disaccharides with LC-fluorescence and LC-MS detection.

Authors:  Nicola Volpi; Fabio Galeotti; Bo Yang; Robert J Linhardt
Journal:  Nat Protoc       Date:  2014-02-06       Impact factor: 13.491

3.  Capillary electrophoresis for total glycosaminoglycan analysis.

Authors:  Ebru Ucakturk; Chao Cai; Lingyun Li; Guoyun Li; Fuming Zhang; Robert J Linhardt
Journal:  Anal Bioanal Chem       Date:  2014-05-11       Impact factor: 4.142

4.  Bottom-up low molecular weight heparin analysis using liquid chromatography-Fourier transform mass spectrometry for extensive characterization.

Authors:  Guoyun Li; Julia Steppich; Zhenyu Wang; Yi Sun; Changhu Xue; Robert J Linhardt; Lingyun Li
Journal:  Anal Chem       Date:  2014-06-17       Impact factor: 6.986

5.  Novel, Precise, Accurate Ion-Pairing Method to Determine the Related Substances of the Fondaparinux Sodium Drug Substance: Low-Molecular-Weight Heparin.

Authors:  Amol A Deshpande; P Madhavan; Girish R Deshpande; Ravi Kumar Chandel; Kaviraj M Yarbagi; Alok R Joshi; J Moses Babu; R Murali Krishna; I M Rao
Journal:  Sci Pharm       Date:  2015-07-22

6.  Structural Characterization of the Low-Molecular-Weight Heparin Dalteparin by Combining Different Analytical Strategies.

Authors:  Antonella Bisio; Elena Urso; Marco Guerrini; Pauline de Wit; Giangiacomo Torri; Annamaria Naggi
Journal:  Molecules       Date:  2017-06-24       Impact factor: 4.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.