Literature DB >> 2345248

Doppler echocardiographic quantitation of cross-sectional area under various hemodynamic conditions: an experimental validation in a canine model of supravalvular aortic stenosis.

A Kitabatake1, K Fujii, J Tanouchi, K Ishihara, M Uematsu, T Masuyama, Y Yoshida, M Hori, T Kamada.   

Abstract

The hemodynamic effects on cross-sectional area calculated with the continuity equation were assessed in canine experiments. In 13 open chest dogs, 46 supravalvular aortic stenoses were created by aortic root banding. The cross-sectional area of the stenosis was calculated by Doppler echocardiography with application of the continuity equation before and after the following hemodynamic interventions: protocol 1, atrial pacing at 90, 120, 150 and 180 beats/min after sinus node crush; protocol 2, preload reduction by mild and severe clamping of the inferior vena cava; and protocol 3, afterload augmentation by mild and severe clamping of the descending aorta. In each observation, a dimension of the stenosis was directly measured by two-dimensional echocardiography, and the cross-sectional area was determined as a reference standard. As a result of the hemodynamic interventions, significant changes were observed in stroke volume and pressure gradient (protocol 1), in cardiac output, stroke volume and pressure gradient (protocol 2) and in heart rate, cardiac output and pressure gradient (protocol 3). Despite these changes in hemodynamic variables, the Doppler-derived cross-sectional area showed no significant change for a given stenosis. In addition, areas calculated with the continuity equation (x) agreed well with those determined by two-dimensional echocardiography (y) (r = 0.96, p less than 0.001, y = 0.97x + 0.02, SEE = +/- 0.06 cm2). Thus, it is concluded that Doppler echocardiography with application of the continuity equation accurately predicts the stenotic cross-sectional area over a wide range of hemodynamic conditions in supravalvular aortic stenosis.

Entities:  

Mesh:

Year:  1990        PMID: 2345248     DOI: 10.1016/0735-1097(90)92843-q

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  1 in total

1.  Echocardiographic evaluation of velocity ratio, velocity time integral ratio, and pulmonary valve area in dogs with pulmonary valve stenosis.

Authors:  Satoko Nishimura; Lance C Visser; Catherine Bélanger; Maureen S Oldach; Catherine T Gunther-Harrington; Joshua A Stern
Journal:  J Vet Intern Med       Date:  2018-08-05       Impact factor: 3.333

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.