Literature DB >> 23450125

Functional impression technique for an ocular prosthesis.

Jitendra Jethwani1, Gayathri S Jethwani, A K Verma.   

Abstract

The loss of an eye is the most devastating, psychologically damaging experience for a patient. All hope to bring such patients back to their accustomed and comfortable life-style rests on a cosmetically acceptable prosthesis. An intra-orbital ocular prosthesis serves the purpose in those defects where the orbital margins are intact. Though the stock eye may match the natural eye's iris and sclera in color, the fit of the prosthesis to the tissue bed may not be as good as desired. Herein, a functional ocular impression technique is presented to achieve a better fit of the prosthesis to the defect area. This technique aims to combine cosmetic excellence with comfort for greater benefit to the patient.

Entities:  

Keywords:  Body temperature wax; Impression technique; Maxillo-facial prosthesis; Ocular prosthesis

Year:  2011        PMID: 23450125      PMCID: PMC3332313          DOI: 10.1007/s13191-011-0099-0

Source DB:  PubMed          Journal:  J Indian Prosthodont Soc        ISSN: 0972-4052


  10 in total

1.  Comparative features of plastic and/or glass in artificial-eye construction.

Authors:  S F ERPF
Journal:  AMA Arch Ophthalmol       Date:  1953-12

2.  Custom made ocular prostheses: a clinical report.

Authors:  L M Sykes
Journal:  J Prosthet Dent       Date:  1996-01       Impact factor: 3.426

3.  Ocular prosthetics: use of a tissue conditioner material to modify a stock ocular prosthesis.

Authors:  R K Ow; S Amrith
Journal:  J Prosthet Dent       Date:  1997-08       Impact factor: 3.426

4.  The fitting and fabrication of a custom resin artificial eye.

Authors:  P Benson
Journal:  J Prosthet Dent       Date:  1977-11       Impact factor: 3.426

5.  Modified ocular prosthesis impression technique.

Authors:  R L Schneider
Journal:  J Prosthet Dent       Date:  1986-04       Impact factor: 3.426

6.  Ocular prosthesis: a physiologic system.

Authors:  S O Bartlett; D J Moore
Journal:  J Prosthet Dent       Date:  1973-04       Impact factor: 3.426

7.  Fabrication of an ocular prosthesis.

Authors:  K E Brown
Journal:  J Prosthet Dent       Date:  1970-08       Impact factor: 3.426

8.  Modified impression method of artificial eye fitting.

Authors:  L Allen; H E Webster
Journal:  Am J Ophthalmol       Date:  1969-02       Impact factor: 5.258

9.  Relining an ocular prosthesis: a case report.

Authors:  R M Smith
Journal:  J Prosthodont       Date:  1995-09       Impact factor: 2.752

10.  Custom ocular prosthetics.

Authors:  J R Cain
Journal:  J Prosthet Dent       Date:  1982-12       Impact factor: 3.426

  10 in total
  2 in total

1.  A simplified technique for fabrication of orbital prosthesis.

Authors:  Neeraj Sharma; G K Thakral; Abhilash Mohapatra; Jyotsna Seth; Pallavi Vashisht
Journal:  J Clin Diagn Res       Date:  2014-06-20

2.  Management of an Anophthalmic Patient by the Fabrication of Custom Made Ocular Prosthesis.

Authors:  Meenakshi Singh; Meghanand Nayak; Jitender Solanki; Sarika Gupta; Anjali Singh
Journal:  Malays J Med Sci       Date:  2015 May-Jun
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.