Red blood cell mechanical stability test.

Oguz K Baskurt1, Herbert J Meiselman.   

Abstract

Red blood cells (RBC) are exposed to various levels of shear stress (SS) during their flow in the circulatory system, yet no significant damage occurs if their mechanical stability is not impaired. Alternatively, normal RBC may be damaged during flow in non-physiological environments and under extreme SS (e.g., extracorporeal circulation, ventricular assist devices). The shear-induced damage may result in hemolysis or in altered mechanical properties of RBC that, in turn, reduces the ability of RBC to withstand further damage by SS. An ektacytometer employing a Couette shearing system was used to apply SS at a constant level of 100 Pa for 300 seconds as a model of sub-hemolytic mechanical stress. The degree of cellular damage during and after the application was assessed by diffraction pattern analysis. The area of the diffraction pattern was found to correlate with the number of RBC in the sheared suspension. Monitoring the ellipse area during the application of gradually increasing SS provides the concentration of the remaining intact RBC and can therefore be used to estimate the hemolytic threshold as a measure of RBC mechanical stability. The hemolytic threshold determined after the mechanical stress application was found to be ~150 Pa, while it was ~250 Pa in the same samples before the SS application. Additionally, SS-elongation index curves recorded before and after the application of the sub-hemolytic SS significantly differed from each other, indicating the impairment in deformability following the mechanical stress. The Couette type ektacytometer can be used as a tool to assess the sub-hemolytic damage to RBC in testing the biomedical equipment.

Entities:  

Keywords:  Erythrocyte mechanical stability; artificial organs; ektacytometry; hemolyic threshold; left ventricular assist device

Mesh:

Year:  2013        PMID: 23445627     DOI: 10.3233/CH-131689

Source DB:  PubMed          Journal:  Clin Hemorheol Microcirc        ISSN: 1386-0291            Impact factor:   2.375


  9 in total

1.  The impact of shear stress on device-induced platelet hemostatic dysfunction relevant to thrombosis and bleeding in mechanically assisted circulation.

Authors:  Zengsheng Chen; Jiafeng Zhang; Tieluo Li; Douglas Tran; Bartley P Griffith; Zhongjun J Wu
Journal:  Artif Organs       Date:  2019-12-17       Impact factor: 3.094

2.  Structure, mechanical properties, and modeling of cyclically compressed pulmonary emboli.

Authors:  Irina N Chernysh; Russell Spiewak; Carolyn L Cambor; Prashant K Purohit; John W Weisel
Journal:  J Mech Behav Biomed Mater       Date:  2020-02-19

Review 3.  Physical Properties of Blood and their Relationship to Clinical Conditions.

Authors:  Tamas Alexy; Jon Detterich; Philippe Connes; Kalman Toth; Elie Nader; Peter Kenyeres; Jose Arriola-Montenegro; Pinar Ulker; Michael J Simmonds
Journal:  Front Physiol       Date:  2022-07-06       Impact factor: 4.755

4.  The effects of stenting on hemorheological parameters: An in vitro investigation under various blood flow conditions.

Authors:  K Kapnisis; H Seidner; M Prokopi; D Pasias; C Pitsillides; A Anayiotos; E Kaliviotis
Journal:  Clin Hemorheol Microcirc       Date:  2019       Impact factor: 2.375

5.  Effects of cholesterol on bilayers with various degrees of unsaturation of their phospholipid tails under mechanical stress.

Authors:  Dongyu Lyu; Lei Zhang; Yong Zhang
Journal:  RSC Adv       Date:  2020-03-17       Impact factor: 4.036

Review 6.  Valid Presumption of Shiga Toxin-Mediated Damage of Developing Erythrocytes in EHEC-Associated Hemolytic Uremic Syndrome.

Authors:  Johanna Detzner; Gottfried Pohlentz; Johannes Müthing
Journal:  Toxins (Basel)       Date:  2020-06-04       Impact factor: 4.546

7.  The distinctive structure and composition of arterial and venous thrombi and pulmonary emboli.

Authors:  Irina N Chernysh; Chandrasekaran Nagaswami; Sofia Kosolapova; Alina D Peshkova; Adam Cuker; Douglas B Cines; Carolyn L Cambor; Rustem I Litvinov; John W Weisel
Journal:  Sci Rep       Date:  2020-03-20       Impact factor: 4.379

8.  Hemocompatibility and safety of the Carmat Total Artifical Heart hybrid membrane.

Authors:  Ulysse Richez; Hector De Castilla; Coralie L Guerin; Nicolas Gendron; Giulia Luraghi; Marc Grimme; Wei Wu; Myriam Taverna; Piet Jansen; Christian Latremouille; Francesco Migliavacca; Gabriele Dubini; Antoine Capel; Alain Carpentier; David M Smadja
Journal:  Heliyon       Date:  2019-12-08

9.  Erythrocyte morphological symmetry analysis to detect sublethal trauma in shear flow.

Authors:  Antony P McNamee; Michael J Simmonds; Masataka Inoue; Jarod T Horobin; Masaya Hakozaki; John F Fraser; Nobuo Watanabe
Journal:  Sci Rep       Date:  2021-12-07       Impact factor: 4.379

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.