OBJECTIVE: The Synergy(®) system, a miniature partial circulatory support device, is implanted with an off-pump, minimally invasive surgical approach. In our experience, implantation of this system is associated with fewer perioperative adverse events than current full support devices. This approach therefore offers the possibility of treating elderly chronic heart-failure patients who might not ordinarily be considered for long-term circulatory support.
METHODS: A total of 54 patients (12 patients ≥ 70 years) were implanted with the Synergy system in an off-pump minithoracotomy procedure. Mean age (54 ± 10 vs 73 ± 3), body surface area (1.9 ± 0.2 vs 1.7 ± 0.1), blood urea nitrogen (BUN) (59 ± 33 vs 91 ± 38), estimated glomerular filtration rate (eGFR) (71 ± 23 vs 50 ± 38) and haemoglobin (12.6 ± 1.9 vs 11.3 ± 1.3) differed significantly between young and old.
RESULTS: Older patients had longer mean durations of support (337 vs 188 days). On average, both groups showed similar improvements (changes from baseline) in haemodynamics (pulmonary capillary wedge pressure -9 ± 16 vs -10 ± 8 mmHg; CO +1.0 ± 0.7 vs 0.9 ± 1.0 l/min, periferical vascular resistance (PVR) -1.2 ± 1.5 vs = 0.8 ± 1.7 Wood) and 6 min walk (107 ± 120 vs 130 ± 121 m). Older patients showed less improvement in peak VO2 (0.5 ± 2.9 vs 1.9 ± 3.0 ml/kg/min). Major adverse events (old vs young) between groups included major bleeding (75 vs 38%), infection (25 vs 38%), renal dysfunction (0 vs 17%) and device-related stroke (8 vs 10%). Mortality rate was 20% for the young and 40% for the elderly.
CONCLUSIONS: Older patients implanted with Synergy had smaller body sizes and worse renal function than younger patients. Both groups experienced similar haemodynamic benefits and functional improvements, though peak VO2 is less improved in the elderly. Risks of bleeding and renal dysfunction appear to be increased in the elderly, though still within acceptable ranges compared with other full support devices. Minimally invasive long-term circulatory support devices, like Synergy, offer a new treatment option to the elderly chronic heart-failure population.

Entities:  

Keywords:  Elderly; Haemodynamic; Heart failure; LVAD; Partial ventricular Support

Mesh:

Year:  2013        PMID: 23444406     DOI: 10.1093/ejcts/ezt041

Source DB:  PubMed          Journal:  Eur J Cardiothorac Surg        ISSN: 1010-7940            Impact factor:   4.191


  4 in total

1.  Hemodynamic assessment of partial mechanical circulatory support: data derived from computed tomography angiographic images and computational fluid dynamics.

Authors:  Christof Karmonik; Sasan Partovi; Fabian Rengier; Hagen Meredig; Mina Berty Farag; Matthias Müller-Eschner; Rawa Arif; Aron-Frederik Popov; Hans-Ulrich Kauczor; Matthias Karck; Arjang Ruhparwar
Journal:  Cardiovasc Diagn Ther       Date:  2015-04

Review 2.  Current approaches to device implantation in pediatric and congenital heart disease patients.

Authors:  Jacob R Miller; Timothy S Lancaster; Pirooz Eghtesady
Journal:  Expert Rev Cardiovasc Ther       Date:  2015-03-03

Review 3.  Ventricular assist device use in congenital heart disease with a comparison to heart transplant.

Authors:  Jacob R Miller; Pirooz Eghtesady
Journal:  J Comp Eff Res       Date:  2014-09       Impact factor: 1.744

Review 4.  Mechanical Circulatory Support in Children.

Authors:  Iki Adachi; Robert D B Jaquiss
Journal:  Curr Cardiol Rev       Date:  2016
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.