Literature DB >> 23442086

Manikin-based performance evaluation of elastomeric respirators against combustion particles.

Xinjian He1, Michael Yermakov, Tiina Reponen, Roy T McKay, Kelley James, Sergey A Grinshpun.   

Abstract

This study investigated the effects of faceseal leakage, breathing flow, and combustion material on the overall (non-size-selective) penetration of combustion particles into P-100 half and full facepiece elastomeric respirators used by firefighters. Respirators were tested on a breathing manikin exposed to aerosols produced by combustion of three materials (wood, paper, and plastic) in a room-size exposure chamber. Testing was performed using a single constant flow (inspiratory flow rate = 30 L/min) and three cyclic flows (mean inspiratory flow rates = 30, 85, and 135 L/min). Four sealing conditions (unsealed, nose-only sealed, nose and chin sealed, and fully sealed) were examined to evaluate the respirator faceseal leakage. Total aerosol concentration was measured inside (C(in)) and outside (C(out)) the respirator using a condensation particle counter. The total penetration through the respirator was determined as a ratio of the two (P = C(in) / C(out)). Faceseal leakage, breathing flow type and rate, and combustion material were all significant factors affecting the performance of the half mask and full facepiece respirators. The efficiency of P-100 respirator filters met the NIOSH certification criteria (penetration ≤0.03%); it was not significantly influenced by the challenge aerosol and flow type, which supports the current NIOSH testing procedure using a single challenge aerosol and a constant airflow. However, contrary to the NIOSH total inward leakage (TIL) test protocol assuming that the result is independent on the type of the tested aerosol, this study revealed that the challenge aerosol significantly affects the particle penetration through unsealed and partially sealed half mask respirators. Increasing leak size increased total particle penetration. The findings point to some limitations of the existing TIL test in predicting protection levels offered by half mask elastomeric respirators.

Mesh:

Substances:

Year:  2013        PMID: 23442086      PMCID: PMC6758539          DOI: 10.1080/15459624.2012.760063

Source DB:  PubMed          Journal:  J Occup Environ Hyg        ISSN: 1545-9624            Impact factor:   2.155


  3 in total

1.  Protection of firefighters against combustion aerosol particles: simulated workplace protection factor of a half-mask respirator (pilot study).

Authors:  James Dietrich; Michael Yermakov; Tiina Reponen; Pramod Kulkarni; Chaolong Qi; Sergey A Grinshpun
Journal:  J Occup Environ Hyg       Date:  2015       Impact factor: 2.155

2.  Effects of breathing frequency and flow rate on the total inward leakage of an elastomeric half-mask donned on an advanced manikin headform.

Authors:  Xinjian He; Sergey A Grinshpun; Tiina Reponen; Roy McKay; Michael S Bergman; Ziqing Zhuang
Journal:  Ann Occup Hyg       Date:  2013-10-08

3.  How does breathing frequency affect the performance of an N95 filtering facepiece respirator and a surgical mask against surrogates of viral particles?

Authors:  Xinjian He; Tiina Reponen; Roy McKay; Sergey A Grinshpun
Journal:  J Occup Environ Hyg       Date:  2014       Impact factor: 2.155