Abstract

We compared the cytoarchitectural features used for the cytologic diagnosis of endometrial adenocarcinoma (EC) using ThinPrep® (TPS = ThinPrep Sample) and BD SurePath™ (SPS = SurePath Sample) preparations. In 20 patients, a direct endometrial sample using the Uterobrush was obtained. Nineteen cases of EA and one case of carcinosarcoma were studied. TPS and SPS were performed according to the manufacturer's recommendations. Moreover, after the TPS preparation, the residual material was also used to prepare an SPS sample (TP-SPS = ThinPrep-Surepath sample). The following points were investigated in both preparations: (1) number of cell clumps; SPS had a significantly higher (20.9) than TPS (1.7) and TP-SPS (10.3); (2) long axis of clumps; SPS had a significantly higher (215.4) than TPS (146.0); (3) rate of cell clumps with longer axes than 200 μm; SPS had a significantly higher (36.7) than TPS (15.2) and TP-SPS (24.2). TP-SPS showed higher values than TPS; (4) nuclear area; TPS had a significant higher (61.2) than SPS (40.8) and TP-SPS (38.6); (5) degree of overlapping nuclei; SPS (3.4) had a significantly higher number of overlapping nuclei than TPS (0.7) and TP-SPS (2.1); (6) nuclear chromatin pattern; no significant differences for the nuclear chromatin pattern were found in the three different methods. The poor performance of TPS versus SPS and TP-SPS was explained with the heavy blood contamination of the samples, and the absence of adhesive coating in the slides is used for TPS. Further investigation of technical differences in liquid-based cytology methodologies is needed.
Copyright © 2013 Wiley Periodicals, Inc., a Wiley company.

Entities:  

Keywords:  SurePath; ThinPrep; cytologic features; endometrial carcinoma; endometrial cytology

Mesh:

Year:  2013        PMID: 23440947     DOI: 10.1002/dc.22921

Source DB:  PubMed          Journal:  Diagn Cytopathol        ISSN: 1097-0339            Impact factor:   1.582


  2 in total

Review 1.  The usefulness of liquid-based cytology for endoscopic ultrasound-guided tissue acquisition of solid pancreatic masses.

Authors:  Masahiro Itonaga; Reiko Ashida; Masayuki Kitano
Journal:  Front Med (Lausanne)       Date:  2022-08-16

2.  Diagnostic value of liquid-based cytology with fine needle aspiration specimens for cervical lymphadenopathy.

Authors:  Nobuyuki Bandoh; Takashi Goto; Toshiaki Akahane; Natsumi Ohnuki; Tomomi Yamaguchi; Hajime Kamada; Yasuaki Harabuchi; Shinya Tanaka; Hiroshi Nishihara
Journal:  Diagn Cytopathol       Date:  2016-01-09       Impact factor: 1.582

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.