Literature DB >> 23440551

Effective low-dose escalation of indocyanine green for near-infrared fluorescent sentinel lymph node mapping in melanoma.

Denis M Gilmore1, Onkar V Khullar, Sylvain Gioux, Alan Stockdale, John V Frangioni, Yolonda L Colson, Sara E Russell.   

Abstract

BACKGROUND: Regional lymph node metastasis is the strongest prognostic factor in patients with melanoma. Published reports that used lymphoscintigraphy with radioactive colloids and blue dye demonstrated accurate sentinel lymph node (SLN) identification in inguinal nodes and axillary nodes, but decreased accuracy in cervical, popliteal, epitrochlear, and parascapular nodes. Near-infrared imaging (NIR) may utilize indocyanine green (ICG) to improve SLN identification. The safety, feasibility and optimal dose of albumin-bound ICG (ICG:HSA) was assessed by NIR to improve SLN mapping in patients with melanoma.
METHODS: Twenty-five consecutive patients with biopsy-proven melanoma underwent standard SLN mapping with preoperatively administered technetium-99 m nanocolloid (Tc-99 m). Intraoperative NIR fluorescence imaging was performed after injection of 1.0 ml of 100, 250 or 500 μM of ICG:HSA in four quadrants around the primary lesion.
RESULTS: NIR fluorescent imaging demonstrated accuracy of 98 % when compared with radioactive colloid. A total of 65 lymph nodes were identified (65 with Tc-99 m, 64 with ICG:HSA). Overall, successful mapping that used either technique was 96 % as one patient failed to map with either modality. As the dose of ICG was increased, the signal-to-background ratio increased from a median of 3.1 to 8.4 to 10.9 over the range of 100, 250, and 500 μM, respectively.
CONCLUSIONS: SLN mapping with ICG:HSA is feasible and accurate in melanoma. ICG has the added advantage of a low cost and an intraoperative technique that does not alter the surgical field, thus allowing for easy identification of SLNs.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23440551     DOI: 10.1245/s10434-013-2905-x

Source DB:  PubMed          Journal:  Ann Surg Oncol        ISSN: 1068-9265            Impact factor:   5.344


  27 in total

Review 1.  NIR fluorescent small molecules for intraoperative imaging.

Authors:  Eric A Owens; Stephanie Lee; JungMun Choi; Maged Henary; Hak Soo Choi
Journal:  Wiley Interdiscip Rev Nanomed Nanobiotechnol       Date:  2015-01-30

Review 2.  Imaging the lymphatic system.

Authors:  Lance L Munn; Timothy P Padera
Journal:  Microvasc Res       Date:  2014-06-21       Impact factor: 3.514

Review 3.  Fluorescent imaging of cancerous tissues for targeted surgery.

Authors:  Lihong Bu; Baozhong Shen; Zhen Cheng
Journal:  Adv Drug Deliv Rev       Date:  2014-07-24       Impact factor: 15.470

Review 4.  Intraoperative fluorescence imaging in thoracic surgery.

Authors:  Andrew D Newton; Jarrod D Predina; Shuming Nie; Philip S Low; Sunil Singhal
Journal:  J Surg Oncol       Date:  2018-08-11       Impact factor: 3.454

5.  Highly Specific and Sensitive Fluorescent Nanoprobes for Image-Guided Resection of Sub-Millimeter Peritoneal Tumors.

Authors:  Aaron H Colby; Samantha M Berry; Ann M Moran; Kristine Amber Pasion; Rong Liu; Yolonda L Colson; Nelson Ruiz-Opazo; Mark W Grinstaff; Victoria L M Herrera
Journal:  ACS Nano       Date:  2017-02-01       Impact factor: 15.881

6.  Identification of metastatic nodal disease in a phase 1 dose-escalation trial of intraoperative sentinel lymph node mapping in non-small cell lung cancer using near-infrared imaging.

Authors:  Denis M Gilmore; Onkar V Khullar; Michael T Jaklitsch; Lucian R Chirieac; John V Frangioni; Yolonda L Colson
Journal:  J Thorac Cardiovasc Surg       Date:  2013-06-19       Impact factor: 5.209

Review 7.  Current innovations in sentinel lymph node mapping for the staging and treatment of resectable lung cancer.

Authors:  Krista J Hachey; Yolonda L Colson
Journal:  Semin Thorac Cardiovasc Surg       Date:  2014-09-16

8.  Safety and feasibility of near-infrared image-guided lymphatic mapping of regional lymph nodes in esophageal cancer.

Authors:  Krista J Hachey; Denis M Gilmore; Katherine W Armstrong; Sean E Harris; Jason L Hornick; Yolonda L Colson; Jon O Wee
Journal:  J Thorac Cardiovasc Surg       Date:  2016-04-11       Impact factor: 5.209

Review 9.  A review of performance of near-infrared fluorescence imaging devices used in clinical studies.

Authors:  B Zhu; E M Sevick-Muraca
Journal:  Br J Radiol       Date:  2015-01       Impact factor: 3.039

10.  Application of albumin-based nanoparticles in the management of cancer.

Authors:  Xinzhe Yu; Chen Jin
Journal:  J Mater Sci Mater Med       Date:  2015-11-26       Impact factor: 3.896

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.