Beta response of LiMgPO4:Tb,B based OSL discs for personnel monitoring applications.

Munish Kumar1, Bhushan Dhabekar, S N Menon, A K Bakshi, J Udhayakumar, M P Chougaonkar, Y S Mayya.   

Abstract

Properties such as high optically stimulated luminescent (OSL) sensitivity, ease of preparation and dose linearity over nine decades (µGy-kGy) make LiMgPO4:Tb, B (LMP) a unique phosphor for dosimetry applications. This led to the investigation of the beta response of highly sensitive LMP-based Teflon-embedded OSL discs for personnel monitoring applications. A PTB beta secondary standard calibration setup (BSS2), which contains three beta sources viz. (147)Pm, (85)Kr and (90)Sr/(90)Y, was used. The relative response with respect to (137)Cs photons for 0.4-mm thick LMP discs was found to be ∼7.32, ∼53.5 and 100 % for (147)Pm, (85)Kr and (90)Sr/(90)Y beta energies, respectively. The response of LMP discs under various filter combinations viz. 0.18-mm thick mylar (25 mg cm(-2)), 0.625-mm thick Poly-allyl-diglycol carbonate (PADC, 81 mg cm(-2)), 1-mm thick polythene (95 mg cm(-2)), 1-mm thick Perspex (118 mg cm(-2)), 1.25-mm thick PADC (162 mg cm(-2)) and 1.6-mm thick (189 mg cm(-2)) Perspex filters was also studied and the ratio of the response of open disc to the response under filters (DOpen/DFilter) of different thicknesses (mg cm(-2)) was evaluated. Studies were also performed for the mixed field of low- ((85)Kr) and high-energy ((90)Sr/(90)Y) beta particles and the DOpen/DFilter ratio was evaluated. The angular dependence of the response of OSL discs to (85)Kr and (90)Sr/(90)Y beta sources was also studied. Studies were also carried out for (204)Tl, (32)P, natural uranium and (106)Ru/(106)Rh beta sources and the ratios of the response of open disc to that of under 1.6-mm thick Perspex (DOpen/DFilter) filter were measured. A study with various beta sources for the evaluation of the DOpen/DFilter ratio was necessary as these ratios are used to estimate the energy of beta particles and to apply the correction factor while evaluating the beta dose/design of dose estimation algorithms.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23440498     DOI: 10.1093/rpd/nct028

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  1 in total

1.  Thermoluminescence Enhancement of LiMgPO4 Crystal Host by Tb3+ and Tm3+ Trivalent Rare-Earth Ions Co-doping.

Authors:  Wojciech Gieszczyk; Barbara Marczewska; Mariusz Kłosowski; Anna Mrozik; Paweł Bilski; Anna Sas-Bieniarz; Paweł Goj; Paweł Stoch
Journal:  Materials (Basel)       Date:  2019-09-05       Impact factor: 3.623