Literature DB >> 23439468

Noninvasive transcutaneous Doppler ultrasound-derived hemodynamic reference ranges in Chinese adolescents.

Grace Y L Ho1, Giles N Cattermole, Stewart S W Chan, Brendan E Smith, Colin A Graham, Timothy H Rainer.   

Abstract

OBJECTIVES: The ultrasonic cardiac output monitor is a noninvasive, quantitative method for measuring and monitoring cardiovascular hemodynamic parameters in patients. The aims of this study were first to establish reference ranges for cardiovascular indices measured by the ultrasonic cardiac output monitor in Chinese children aged 12-18 yr, second to assess the interobserver reliability of the method, and third to compare these ranges with a Caucasian group from Australia. DESIGN, SETTING, AND
SUBJECTS: This was a population-based cross-sectional cohort study of Chinese adolescents 12-18 years old, performed in secondary schools in Hong Kong.
INTERVENTIONS: Ultrasonic cardiac output monitor scans were performed on each subject to measure stroke volume, cardiac output, and systemic vascular resistance together with standard oscillometric measurement of blood pressure and heart rate. Ultrasonic cardiac output monitor parameters were also standardized by deriving body surface area referenced indices. Normal ranges were defined as lying within two standard deviations on either side of the mean. To assess interobserver variability, a second, blinded operator repeated 17% of scans.
MEASUREMENTS AND MAIN RESULTS: A total of 590 Chinese adolescents (49% boys) were scanned. Normal ranges for cardiac output, cardiac index, stroke volume, stroke volume index, stroke volume resistance, and systemic vascular resistance index are presented. Males had a significantly higher mean stroke volume, cardiac output, and systemic vascular resistance index compared with females (p < 0.05), but no significant differences were found for the indexed values. When compared with a group of 31 Australian Caucasian adolescents (71% boys), Chinese adolescents have a significantly lower cardiac output and stroke volume (p <0.05), but these differences disappeared when adjusted for body surface area (i.e., stroke volume index, cardiac index, and systemic vascular resistance index). Interobserver variability of ultrasonic cardiac output monitor-derived stroke volume showed a coefficient of variation of 10.2%, a correlation coefficient of 0.90 (95% confidence interval 0.85-0.93), while Bland-Altman analysis showed a mean bias of 1.5% (95% limits of agreement were -19.9% to 23.0%).
CONCLUSIONS: This study presents normal values for cardiovascular indices in Chinese adolescents using the ultrasonic cardiac output monitor. When referenced to body surface area, the differences between Caucasians and Chinese were insignificant.

Entities:  

Mesh:

Year:  2013        PMID: 23439468     DOI: 10.1097/PCC.0b013e3182772f78

Source DB:  PubMed          Journal:  Pediatr Crit Care Med        ISSN: 1529-7535            Impact factor:   3.624


  5 in total

1.  Urgent ultrasound guided hemodynamic assessments by a pediatric medical emergency team: a pilot study.

Authors:  David J Zorko; Karen Choong; Jonathan Gilleland; Barbara Agar; Shawn Baker; Cindy Brennan; Eleanor Pullenayegum
Journal:  PLoS One       Date:  2013-06-25       Impact factor: 3.240

2.  The normal ranges of cardiovascular parameters measured using the ultrasonic cardiac output monitor.

Authors:  Giles N Cattermole; P Y Mia Leung; Grace Y L Ho; Peach W S Lau; Cangel P Y Chan; Stewart S W Chan; Brendan E Smith; Colin A Graham; Timothy H Rainer
Journal:  Physiol Rep       Date:  2017-03

3.  Efficacy of Mobile Apps to Support the Care of Patients With Diabetes Mellitus: A Systematic Review and Meta-Analysis of Randomized Controlled Trials.

Authors:  Bráulio Cezar Bonoto; Vânia Eloisa de Araújo; Isabella Piassi Godói; Lívia Lovato Pires de Lemos; Brian Godman; Marion Bennie; Leonardo Mauricio Diniz; Augusto Afonso Guerra Junior
Journal:  JMIR Mhealth Uhealth       Date:  2017-03-01       Impact factor: 4.773

4.  Age-specific non-invasive transcutaneous Doppler ultrasound derived haemodynamic reference ranges in elderly Chinese adults.

Authors:  Cangel Pui-Yee Chan; Nandini Agarwal; King-Keung Sin; Sangeeta Narain; Brendan E Smith; Colin A Graham; Timothy H Rainer
Journal:  BBA Clin       Date:  2014-09-28

5.  Stroke volume and cardiac output non-invasive monitoring based on brachial oscillometry-derived pulse contour analysis: Explanatory variables and reference intervals throughout life (3-88 years).

Authors:  Yanina Zócalo; Victoria García-Espinosa; Juan M Castro; Agustina Zinoveev; Mariana Marin; Pedro Chiesa; Alejandro Díaz; Daniel Bia
Journal:  Cardiol J       Date:  2020-03-24       Impact factor: 2.737