Literature DB >> 23439172

Self-adjustment of insulin dose using graphically depicted self-monitoring of blood glucose measurements in patients with type 1 diabetes mellitus.

Andreas Reichel1, Hannes Rietzsch, Barbara Ludwig, Katrin Röthig, Annette Moritz, Stefan R Bornstein.   

Abstract

BACKGROUND: There is a need for patients to be able to adjust their insulin doses accurately and independently during continuous subcutaneous insulin infusion (CSII) therapy in order to avoid glycemic excursions and improve glycemic control. Use of new technology has the potential to aid patients in visualizing their circadian patterns and improving their understanding of data provided by self-monitored blood glucose (SMBG) measurements.
METHODS: A 24-week crossover study was performed in 25 patients with type 1 diabetes mellitus using CSII and SMBG. Patients were randomized either to entering blood glucose data into handwritten logbooks or to using the Accu-Chek SmartPix information management system (IMS) coupled with instructions from a training manual to aid interpretation of the IMS readings. Patients analyzed these chart readings every 2 weeks, and outpatient visits were scheduled for both arms every 6 weeks.
RESULTS: There was a significantly lower mean overall blood glucose level with the IMS compared with use of a logbook (139 ± 16.2 versus 150 ± 19.8 mg/dl; Δ = 10.8 mg/dl; p < .01), and a significantly higher proportion of blood glucose values was in the target range compared with use of a logbook (43.6% versus 38.5%; p < .001). Hypoglycemic events were also significantly lower with the IMS compared with logbooks (3.7 fewer events/6 weeks; p < .05). There was no significant difference between groups in the daily frequency of SMBG measurements.
CONCLUSIONS: The use of an IMS, coupled with an easily understood training manual, enables patients to improve glycemic control by performing accurate and timely self-adjustments to their insulin regimens.
© 2012 Diabetes Technology Society.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23439172      PMCID: PMC3692228          DOI: 10.1177/193229681300700119

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  9 in total

1.  3rd Annual Symposium on Self Monitoring of Blood Glucose (SMBG) Applications and Beyond, May 7-8, 2010, London, UK.

Authors:  Nebojsa M Lalic; Bernhard Landers
Journal:  Diabetes Technol Ther       Date:  2010-10-08       Impact factor: 6.118

Review 2.  Contemporary management of patients with type 1 diabetes.

Authors:  Sanjeev N Mehta; Joseph I Wolfsdorf
Journal:  Endocrinol Metab Clin North Am       Date:  2010-09       Impact factor: 4.741

3.  Intensive diabetes treatment and cardiovascular disease in patients with type 1 diabetes.

Authors:  David M Nathan; Patricia A Cleary; Jye-Yu C Backlund; Saul M Genuth; John M Lachin; Trevor J Orchard; Philip Raskin; Bernard Zinman
Journal:  N Engl J Med       Date:  2005-12-22       Impact factor: 91.245

Review 4.  Health technologies for monitoring and managing diabetes: a systematic review.

Authors:  Elizabeth Russell-Minda; Jeffrey Jutai; Mark Speechley; Kaitlin Bradley; Anna Chudyk; Robert Petrella
Journal:  J Diabetes Sci Technol       Date:  2009-11-01

5.  Display of glucose distributions by date, time of day, and day of week: new and improved methods.

Authors:  David Rodbard
Journal:  J Diabetes Sci Technol       Date:  2009-11-01

Review 6.  The role of self-monitoring of blood glucose in the care of people with diabetes: report of a global consensus conference.

Authors:  Richard M Bergenstal; James R Gavin
Journal:  Am J Med       Date:  2005-09       Impact factor: 4.965

Review 7.  Practical steps to improving the management of type 1 diabetes: recommendations from the Global Partnership for Effective Diabetes Management.

Authors:  P Aschner; E Horton; L A Leiter; N Munro; J S Skyler
Journal:  Int J Clin Pract       Date:  2010-02       Impact factor: 2.503

8.  The effect of intensive treatment of diabetes on the development and progression of long-term complications in insulin-dependent diabetes mellitus.

Authors:  D M Nathan; S Genuth; J Lachin; P Cleary; O Crofford; M Davis; L Rand; C Siebert
Journal:  N Engl J Med       Date:  1993-09-30       Impact factor: 91.245

Review 9.  Self-Monitoring of Blood Glucose (SMBG) in insulin- and non-insulin-using adults with diabetes: consensus recommendations for improving SMBG accuracy, utilization, and research.

Authors:  Irl B Hirsch; Bruce W Bode; Belinda P Childs; Kelly L Close; William A Fisher; James R Gavin; Barry H Ginsberg; Charles H Raine; Carol A Verderese
Journal:  Diabetes Technol Ther       Date:  2008-12       Impact factor: 6.118

  9 in total
  3 in total

1.  Performance assessment of a closed-loop system for diabetes management.

Authors:  A Martinez-Millana; G Fico; C Fernández-Llatas; V Traver
Journal:  Med Biol Eng Comput       Date:  2015-02-11       Impact factor: 2.602

2.  7(th) Annual Symposium on Self-Monitoring of Blood Glucose (SMBG), May 8-10, 2014, Helsinki, Finland.

Authors:  Christopher G Parkin; Anita Mlinac; Rolf Hinzmann
Journal:  Diabetes Technol Ther       Date:  2014-09-11       Impact factor: 6.118

3.  Improving the Quality of Outpatient Diabetes Care Using an Information Management System: Results From the Observational VISION Study.

Authors:  Joerg Weissmann; Angelika Mueller; Diethelm Messinger; Christopher G Parkin; Ildiko Amann-Zalan
Journal:  J Diabetes Sci Technol       Date:  2015-07-29
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.