Literature DB >> 23436163

Double acetabular wall--a misleading point for hip arthroplasty: an anatomical, radiological, clinical study.

Firooz Madadi1, Hamed Yazdanshenas, Firoozeh Madadi, Shahrzad Bazargan-Hejazi.   

Abstract

PURPOSE: Despite the great attention focused on cup positioning in primary total hip arthroplasty (PTHA), it is surprising to find so few studies that have dealt with cup placement. A common thwarting problem for correct cup placement during PTHA is the existence of osteophytes, which obscure the anatomical landmarks. In this study we aimed to evaluate the morphology of acetabular osteophyte formation in patients with osteoarthritis.
METHOD: We evaluated 276 patients with hip complaints, using plain X-rays and CT scans.
RESULTS: Of these patients, 57 underwent surgery. We developed a staging system for central osteophytes in hip osteoarthritis based on the radiographic and anatomical findings of our patients.
CONCLUSION: We recommend routine use of CT scans for patients scheduled for PTHA in order to assess the stage of osteophyte before surgery and, thus, reduce the risk of failure resulting from the interrupted acetabular landmarks.

Entities:  

Mesh:

Year:  2013        PMID: 23436163      PMCID: PMC3664162          DOI: 10.1007/s00264-013-1780-1

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  20 in total

Review 1.  Dislocation after total hip arthroplasty: implant design and orientation.

Authors:  Robert L Barrack
Journal:  J Am Acad Orthop Surg       Date:  2003 Mar-Apr       Impact factor: 3.020

2.  Intra- and extra-articular planes of reference for use in total hip arthroplasty: a preliminary study.

Authors:  Jerome Hausselle; Pierre Etienne Moreau; Loic Wessely; Emmanuel de Thomasson; Ayman Assi; Sebastien Parratte; Jerome Essig; Wafa Skalli
Journal:  Int Orthop       Date:  2012-03-21       Impact factor: 3.075

3.  Primary arthroscopic stabilization for a first-time anterior dislocation of the shoulder.

Authors:  Gunaratnam Shyamalan; Koushik Ghosh
Journal:  J Bone Joint Surg Am       Date:  2008-11       Impact factor: 5.284

4.  Validation of navigation assisted cup placement in total hip arthroplasty.

Authors:  M Ajith Kumar; M Shantharam Shetty; Kanthi G Kiran; Abhishek R Kini
Journal:  Int Orthop       Date:  2011-05-03       Impact factor: 3.075

Review 5.  Is there evidence for a superior method of socket fixation in hip arthroplasty? A systematic review.

Authors:  Dean Pakvis; Gijs van Hellemondt; Enrico de Visser; Wilco Jacobs; Maarten Spruit
Journal:  Int Orthop       Date:  2011-03-15       Impact factor: 3.075

Review 6.  Cementless acetabular revision: past, present, and future. Revision total hip arthroplasty: the acetabular side using cementless implants.

Authors:  Luis Pulido; Sridhar R Rachala; Miguel E Cabanela
Journal:  Int Orthop       Date:  2011-01-14       Impact factor: 3.075

7.  Esophageal and esophagogastric junction cancers.

Authors:  Jaffer A Ajani; James S Barthel; David J Bentrem; Thomas A D'Amico; Prajnan Das; Crystal S Denlinger; Charles S Fuchs; Hans Gerdes; Robert E Glasgow; James A Hayman; Wayne L Hofstetter; David H Ilson; Rajesh N Keswani; Lawrence R Kleinberg; W Michael Korn; A Craig Lockhart; Mary F Mulcahy; Mark B Orringer; Raymond U Osarogiagbon; James A Posey; Aaron R Sasson; Walter J Scott; Stephen Shibata; Vivian E M Strong; Thomas K Varghese; Graham Warren; Mary Kay Washington; Christopher Willett; Cameron D Wright
Journal:  J Natl Compr Canc Netw       Date:  2011-08-01       Impact factor: 11.908

8.  Acetabular anatomy and the transacetabular fixation of screws in total hip arthroplasty.

Authors:  R C Wasielewski; L A Cooperstein; M P Kruger; H E Rubash
Journal:  J Bone Joint Surg Am       Date:  1990-04       Impact factor: 5.284

9.  Musculoskeletal manifestations of Paget's disease of bone.

Authors:  R D Altman
Journal:  Arthritis Rheum       Date:  1980-10

10.  Dislocations after total hip-replacement arthroplasties.

Authors:  G E Lewinnek; J L Lewis; R Tarr; C L Compere; J R Zimmerman
Journal:  J Bone Joint Surg Am       Date:  1978-03       Impact factor: 5.284

View more
  7 in total

1.  Anterior decompression with single segmental spinal interbody fusion for Denis type B thoracolumbar burst fracture: a midterm follow-up study.

Authors:  Jiaguang Tang; Yishan Liu; Yuan Hu; Zheng Cao; Xiang Lu; Bin Lin
Journal:  Int Orthop       Date:  2013-09-06       Impact factor: 3.075

2.  A new method for tibial torsion measurement by computerized tomography.

Authors:  Firooz Madadi; Firoozeh Madadi; Arash Maleki; Arya Nick Shamie; Eleby Rudolph Washington; Hamed Yazdanshenas
Journal:  J Orthop       Date:  2015-10-04

3.  What MRI Findings Predict Failure 10 Years After Surgery for Femoroacetabular Impingement?

Authors:  Markus S Hanke; Simon D Steppacher; Helen Anwander; Stefan Werlen; Klaus A Siebenrock; Moritz Tannast
Journal:  Clin Orthop Relat Res       Date:  2017-04       Impact factor: 4.176

4.  Senior Managed Care System for Hip Fracture in the United States.

Authors:  Hamed Yazdanshenas; Eleby R Washington; Arya Nick Shamie; Firooz Madadi; Eleby R Washington
Journal:  Clin Orthop Surg       Date:  2016-02-13

5.  Anterior D-rod and titanium mesh fixation for acute mid-lumbar burst fracture with incomplete neurologic deficits: A prospective study of 56 consecutive patients.

Authors:  Zhe-Yuan Huang; Zhen-Qi Ding; Hao-Yuan Liu; Jun Fang; Hui Liu; Mo Sha
Journal:  Indian J Orthop       Date:  2015 Jul-Aug       Impact factor: 1.251

6.  Central acetabular osteophytes (CAO) are more prevalent in the borderline developmental dysplastic hip (BDDH) patients: a propensity-score matched CT study.

Authors:  Fan Yang; Hong-Jie Huang; Xin Zhang; Jian-Quan Wang; Zi-Yi He; Yan Xu
Journal:  J Orthop Surg Res       Date:  2022-03-12       Impact factor: 2.359

7.  Hip preservation surgery and the acetabular fossa.

Authors:  Pablo A Slullitel; Daniel Coutu; Martin A Buttaro; Paul Edgar Beaule; George Grammatopoulos
Journal:  Bone Joint Res       Date:  2020-12       Impact factor: 4.410

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.