Literature DB >> 23435807

Real-time particle size analysis using focused beam reflectance measurement as a process analytical technology tool for a continuous granulation-drying-milling process.

Vijay Kumar1, Michael K Taylor, Amit Mehrotra, William C Stagner.   

Abstract

Focused beam reflectance measurement (FBRM) was used as a process analytical technology tool to perform inline real-time particle size analysis of a proprietary granulation manufactured using a continuous twin-screw granulation-drying-milling process. A significant relationship between D20, D50, and D80 length-weighted chord length and sieve particle size was observed with a p value of <0.0001 and R(2) of 0.886. A central composite response surface statistical design was used to evaluate the effect of granulator screw speed and Comil® impeller speed on the length-weighted chord length distribution (CLD) and particle size distribution (PSD) determined by FBRM and nested sieve analysis, respectively. The effect of granulator speed and mill speed on bulk density, tapped density, Compressibility Index, and Flowability Index were also investigated. An inline FBRM probe placed below the Comil-generated chord lengths and CLD data at designated times. The collection of the milled samples for sieve analysis and PSD evaluation were coordinated with the timing of the FBRM determinations. Both FBRM and sieve analysis resulted in similar bimodal distributions for all ten manufactured batches studied. Within the experimental space studied, the granulator screw speed (650-850 rpm) and Comil® impeller speed (1,000-2,000 rpm) did not have a significant effect on CLD, PSD, bulk density, tapped density, Compressibility Index, and Flowability Index (p value > 0.05).

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23435807      PMCID: PMC3666011          DOI: 10.1208/s12249-013-9934-4

Source DB:  PubMed          Journal:  AAPS PharmSciTech        ISSN: 1530-9932            Impact factor:   3.246


  5 in total

1.  EFFECT OF CERTAIN TABLET FORMULATION FACTORS ON DISSOLUTION RATE OF THE ACTIVE INGREDIENT. II. GRANULE SIZE, STARCH CONCENTRATION, AND COMPRESSION PRESSURE.

Authors:  G LEVY; J M ANTKOWIAK; J A PROCKNAL; D C WHITE
Journal:  J Pharm Sci       Date:  1963-11       Impact factor: 3.534

2.  Study growth kinetics in fluidized bed granulation with at-line FBRM.

Authors:  Xinhui Hu; John C Cunningham; Denita Winstead
Journal:  Int J Pharm       Date:  2007-07-03       Impact factor: 5.875

3.  The effect of granule properties on the pore structure of tablets of sucrose and lactose.

Authors:  D Ganderton; A B Selkirk
Journal:  J Pharm Pharmacol       Date:  1970-05       Impact factor: 3.765

4.  Effect of size on other physical properties of granules and their corresponding tablets.

Authors:  A M Marks; J J Sciarra
Journal:  J Pharm Sci       Date:  1968-03       Impact factor: 3.534

5.  Reduced tabletability of roller compacted granules as a result of granule size enlargement.

Authors:  Changquan Calvin Sun; Micah W Himmelspach
Journal:  J Pharm Sci       Date:  2006-01       Impact factor: 3.534

  5 in total
  5 in total

Review 1.  Process optimization and particle engineering of micronized drug powders via milling.

Authors:  A Brunaugh; H D C Smyth
Journal:  Drug Deliv Transl Res       Date:  2018-12       Impact factor: 4.617

Review 2.  Current Status and Challenges of Analytical Methods for Evaluation of Size and Surface Modification of Nanoparticle-Based Drug Formulations.

Authors:  Yuki Takechi-Haraya; Takashi Ohgita; Yosuke Demizu; Hiroyuki Saito; Ken-Ichi Izutsu; Kumiko Sakai-Kato
Journal:  AAPS PharmSciTech       Date:  2022-05-20       Impact factor: 4.026

3.  Real-time Particle Size Analysis Using the Focused Beam Reflectance Measurement Probe for In Situ Fabrication of Polyacrylamide-Filler Composite Materials.

Authors:  Sivashunmugam Sankaranarayanan; Blaž Likozar; Rodrigo Navia
Journal:  Sci Rep       Date:  2019-07-12       Impact factor: 4.379

Review 4.  Model-Based Scale-Up Methodologies for Pharmaceutical Granulation.

Authors:  Eun Ha Jang; Yun Sang Park; Min-Soo Kim; Du Hyung Choi
Journal:  Pharmaceutics       Date:  2020-05-14       Impact factor: 6.321

Review 5.  Metamorphosis of Twin Screw Extruder-Based Granulation Technology: Applications Focusing on Its Impact on Conventional Granulation Technology.

Authors:  Rajat Radhakrishna Rao; Abhijeet Pandey; Aswathi R Hegde; Vijay Induvadan Kulkarni; Chetan Chincholi; Vinay Rao; Indu Bhushan; Srinivas Mutalik
Journal:  AAPS PharmSciTech       Date:  2021-12-14       Impact factor: 3.246

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.