Literature DB >> 23435745

Balloon coating with rapamycin using an on-site coating device.

Jörg Schmehl1, Jürgen von der Ruhr, Markus Dobratz, Rainer Kehlbach, Isabelle Braun, Tim-Oliver Greiner, Claus D Claussen, Boris Behnisch.   

Abstract

PURPOSE: The efficacy of drug-eluting balloons has been demonstrated in clinical trials. The drug predominantly used is paclitaxel because of its lipophilic properties and the rapid onset of action. The aim of the investigation was to evaluate the feasibility and efficacy of an alternative balloon coating with rapamycin that can be applied on site.
METHODS: The balloon coating (3.0/18 and 3.0/12 mm, Cathy No. 4, Translumina GmbH) with rapamycin was conducted with a coating machine (Translumina GmbH). Concentrations were 2, 2 × 2, 3, and 4 %. Measurements regarding the amount of substance released to the vessel wall were carried out on explanted porcine coronaries by means of ultraviolet and visible-light spectroscopy. Inflation time varied between 30 and 120 s. The biological effect of the coating was evaluated in a porcine peripheral overstretch and stent implantation model.
RESULTS: The amount of rapamycin on the balloon surface ranged from 558 ± 108 μg for the 2 % solution to 1,441 ± 228 μg in the 4 % solution. An amount of 95 ± 63-193 ± 113 μg was released into the vessel wall. The quantitative measurements of the angiographic examinations 4 weeks after treatment revealed a reduction of diameter stenosis from 20.6 ± 17.4 % in the control group to 11.6 ± 5.5 % in the drug-eluting balloon group.
CONCLUSION: A balloon coating with rapamycin omitting an excipient is possible with a dose-adjustable coating machine. However, the biological effects are moderate, which make further optimization of the coating process and evaluation of appropriate excipients necessary.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23435745     DOI: 10.1007/s00270-013-0583-5

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  2 in total

Review 1.  Advances in Percutaneous Therapies for Peripheral Artery Disease: Drug-Coated Balloons.

Authors:  Rasha F Al-Bawardy; Stephen W Waldo; Kenneth Rosenfield
Journal:  Curr Cardiol Rep       Date:  2017-08-24       Impact factor: 2.931

Review 2.  Drug-Eluting Balloons in the Treatment of Coronary De Novo Lesions: A Comprehensive Review.

Authors:  Rasmus Kapalu Broge Richelsen; Thure Filskov Overvad; Svend Eggert Jensen
Journal:  Cardiol Ther       Date:  2016-07-06
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.