Literature DB >> 23433351

Relationship between macular ganglion cell complex thickness and macular outer retinal thickness: a spectral-domain optical coherence tomography study.

Yoshiyuki Kita1, Ritsuko Kita, Asuka Takeyama, Ayako Anraku, Goji Tomita, Ivan Goldberg.   

Abstract

BACKGROUND: To assess the relationship between macular ganglion cell complex and macular outer retinal thicknesses.
DESIGN: Case-control study. PARTICIPANTS: Forty-two normal eyes and 91 eyes with primary open-angle glaucoma were studied.
METHODS: Spectral-domain optical coherence tomography (RTVue-100) was used to measure the macular ganglion cell complex and macular outer retinal thickness. Ganglion cell complex to outer retinal thickness ratio was also calculated. MAIN OUTCOME MEASURES: The relationships between the ganglion cell complex and outer retinal thicknesses and between the ganglion cell complex to outer retinal thickness ratio and outer retinal thickness were evaluated.
RESULTS: There was a positive correlation between ganglion cell complex and outer retinal thicknesses in the normal group and the glaucoma group (r = 0.53, P < 0.001 and r = 0.42, P < 0.001, respectively). In that respect, there was no correlation between ganglion cell complex to outer retinal thickness ratio and outer retinal thickness in the both groups (r = -0.07, P = 0.657, and r = 0.04, P = 0.677, respectively). The ganglion cell complex to outer retinal thickness ratio was 55.65% in the normal group, 45.07% in the glaucoma group. This difference was statistically significant.
CONCLUSIONS: The ganglion cell complex thickness may be affected by outer retinal thickness, and there is individual variation in the outer retinal thickness. Therefore, when determining the ganglion cell complex, it seems necessary to consider the outer retinal thickness as well. We propose the ratio as a suitable parameter to account for individual variations in outer retinal thickness.
© 2013 The Authors. Clinical and Experimental Ophthalmology © 2013 Royal Australian and New Zealand College of Ophthalmologists.

Entities:  

Keywords:  ganglion cell complex; glaucoma; outer retinal thickness; ratio; spectral-domain optical coherence tomography

Mesh:

Year:  2013        PMID: 23433351     DOI: 10.1111/ceo.12089

Source DB:  PubMed          Journal:  Clin Exp Ophthalmol        ISSN: 1442-6404            Impact factor:   4.207


  9 in total

1.  Influence of axial length on ganglion cell complex (GCC) thickness and on GCC thickness to retinal thickness ratios in young adults.

Authors:  Asuka Takeyama; Yoshiyuki Kita; Ritsuko Kita; Goji Tomita
Journal:  Jpn J Ophthalmol       Date:  2013-11-19       Impact factor: 2.447

2.  Evaluation of spectral domain optical coherence tomography parameters in ocular hypertension, preperimetric, and early glaucoma.

Authors:  Tuğba Aydogan; BetÜl İlkay Sezgin Akçay; Esra Kardeş; Ahmet Ergin
Journal:  Indian J Ophthalmol       Date:  2017-11       Impact factor: 1.848

3.  Optical coherence tomography for glaucoma diagnosis: An evidence based meta-analysis.

Authors:  Vinay Kansal; James J Armstrong; Robert Pintwala; Cindy Hutnik
Journal:  PLoS One       Date:  2018-01-04       Impact factor: 3.240

4.  Circumpapillary ganglion cell complex thickness to diagnose glaucoma: A pilot study.

Authors:  Yoshiyuki Kita; Norihisa Soutome; Daisuke Horie; Ritsuko Kita; Gaborá Hollό
Journal:  Indian J Ophthalmol       Date:  2017-01       Impact factor: 1.848

5.  Analysis of inner and outer retinal layers using spectral domain optical coherence tomography automated segmentation software in ocular hypertensive and glaucoma patients.

Authors:  Pilar Cifuentes-Canorea; Jorge Ruiz-Medrano; Rosa Gutierrez-Bonet; Pablo Peña-Garcia; Federico Saenz-Frances; Julian Garcia-Feijoo; Jose Maria Martinez-de-la-Casa
Journal:  PLoS One       Date:  2018-04-19       Impact factor: 3.240

6.  Glaucomatous Maculopathy: Thickness Differences on Inner and Outer Macular Layers between Ocular Hypertension and Early Primary Open-Angle Glaucoma Using 8 × 8 Posterior Pole Algorithm of SD-OCT.

Authors:  Jose Javier Garcia-Medina; Monica Del-Rio-Vellosillo; Ana Palazon-Cabanes; Maria Dolores Pinazo-Duran; Vicente Zanon-Moreno; Maria Paz Villegas-Perez
Journal:  J Clin Med       Date:  2020-05-16       Impact factor: 4.241

7.  Circumpapillary structure-function relationships with microperimetry and spectral domain optical coherence tomography in glaucoma: a pilot study.

Authors:  Yoshiyuki Kita; Gábor Holló; Akiko Murai; Ritsuko Kita; Tsunehiro Saito; Akito Hirakata
Journal:  Clin Ophthalmol       Date:  2018-12-06

8.  Differences of Intrasession Reproducibility of Circumpapillary Total Retinal Thickness and Circumpapillary Retinal Nerve Fiber Layer Thickness Measurements Made with the RS-3000 Optical Coherence Tomograph.

Authors:  Yoshiyuki Kita; Gábor Hollό; Ritsuko Kita; Daisuke Horie; Makoto Inoue; Akito Hirakata
Journal:  PLoS One       Date:  2015-12-14       Impact factor: 3.240

9.  The development of a reference database with the Topcon 3D OCT-1 Maestro.

Authors:  Michael Chaglasian; Murray Fingeret; Pinakin Gunvant Davey; Wei-Chieh Huang; Danny Leung; Edmund Ng; Charles A Reisman
Journal:  Clin Ophthalmol       Date:  2018-05-07
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.