Literature DB >> 23427479

Methodology and bias in assessing compliance with a surgical safety checklist.

Sabrina J Poon1, Scott L Zuckerman, Rajshri Mainthia, Scott L Hagan, D Timothy Lockney, Alexander Zotov, Ginger E Holt, Marc L Bennett, Shilo Anders, Daniel J France.   

Abstract

BACKGROUND: Surgical safety checklists, such as the perioperative time-out, have been shown to improve performance on a variety of patient safety measures. A variety of methods have been used to assess compliance with the perioperative time-out, but no standardized methodology with a reliable observer group currently exists. An observation-based methodology was used to assess time-out compliance at an academic medical center.
METHODS: A single observer group made up of medical students and nurses recorded compliance with each of the 11 standardized items of the time-out. A total of 193 time-out procedures were observed, 48 by medical students and 145 by nurses.
RESULTS: One item (procedure to be performed) achieved > 95% compliance. Three items (surgical site; availability of necessary blood products, implants, devices; and start of antibiotics) achieved 80%-95% compliance. Seven items achieved < 80% compliance (presence of required members of procedure team, presence of person who marked patient, patient identity, side marking, relevant images, allergies, and discussion of relevant special considerations). Compliance with the four core time-out items was 78.2%. Of the 11 items on the time-out being evaluated, there was a statistically significant difference between medical student and nursing observations for 10 items (p < .05).
CONCLUSIONS: In our cohort of observed time-outs, the compliance rate was low, calling into question time-out quality, and, more importantly, patient safety. Measures must be taken by large hospitals to regularly audit time-out compliance and create effective programming to improve performance. Although observational assessment is an effective method to assess compliance with surgical safety checklists, observer group bias has the potential to skew results.

Entities:  

Mesh:

Year:  2013        PMID: 23427479     DOI: 10.1016/s1553-7250(13)39011-4

Source DB:  PubMed          Journal:  Jt Comm J Qual Patient Saf        ISSN: 1553-7250


  2 in total

1.  Attitudes and compliance with the WHO surgical safety checklist: a survey among surgeons and operating room staff in 138 hospitals in China.

Authors:  Jie Tan; James Reeves Mbori Ngwayi; Zhaohan Ding; Yufa Zhou; Ming Li; Yujie Chen; Bingtao Hu; Jinping Liu; Daniel Edward Porter
Journal:  Patient Saf Surg       Date:  2021-01-06

2.  Retrospective record review in proactive patient safety work - identification of no-harm incidents.

Authors:  Kristina Schildmeijer; Maria Unbeck; Olav Muren; Joep Perk; Karin Pukk Härenstam; Lena Nilsson
Journal:  BMC Health Serv Res       Date:  2013-07-22       Impact factor: 2.655

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.