Literature DB >> 23424023

Safety and outcomes following hybrid balloon and balloon-only procedures using a multifunction, multisinus balloon dilation tool.

David Brodner1, Nathan Nachlas, Presley Mock, Theodore Truitt, Michael Armstrong, Raza Pasha, Christopher Jung, James Atkins.   

Abstract

BACKGROUND: A multicenter prospective study was conducted to assess the safety and sustained effectiveness of a new instrument possessing multifunctionality as an ostium seeker, suction-irrigator, and malleable balloon-dilator indicated for treating multiple sinuses.
METHODS: Endoscopic balloon-only and hybrid-balloon procedures involving dilation of the frontal recesses, maxillary ostia, and/or sphenoid sinus ostia were performed in 175 patients. One-month follow-up was required for all patients. The first 50 patients enrolled also consented to a 1-year follow-up. Complications and sinus symptom severity were assessed at the 1-month visit. Symptom severity and ostial patency of the treated sinuses were evaluated at the 1-year visit.
RESULTS: A total of 497 balloon dilations (279 frontal, 138 sphenoid, and 80 maxillary) were attempted in 175 patients. Over 96% (479/497) of the attempted sinus dilations were successfully completed, while 18 dilations were converted to traditional dissection due to an inability to access or dilate the targeted anatomy. Two (1.1%) nonserious adverse events were reported following hybrid-balloon dilation and both were unrelated to the device or the procedure. Forty-four of 50 patients in the extended follow-up cohort completed the 1-year follow-up. Sinus symptom improvement in this group improved significantly from an average severity of 1.9 ± 1.1 to 0.8 ± 0.7 (p < 0.0001) and 1-year ostial patency was 91.6% (76/83). One revision surgery (2.3%) was performed.
CONCLUSION: These results indicate that a multifunctional, malleable, balloon-dilating device can be safely and successfully used to treat multiple sinuses with sustained ostial patency and symptom improvement for at least 1 year.
© 2013 ARS-AAOA, LLC.

Entities:  

Keywords:  FESS; balloon dilation; patency; quality of life; rhinosinusitis; safety

Mesh:

Year:  2013        PMID: 23424023     DOI: 10.1002/alr.21156

Source DB:  PubMed          Journal:  Int Forum Allergy Rhinol        ISSN: 2042-6976            Impact factor:   3.858


  5 in total

Review 1.  Comprehensive review on endonasal endoscopic sinus surgery.

Authors:  Rainer K Weber; Werner Hosemann
Journal:  GMS Curr Top Otorhinolaryngol Head Neck Surg       Date:  2015-12-22

2.  Balloon catheter dilation technology combined with a fibrolaryngoscope to treat a maxillary sinus cyst.

Authors:  Jianxin Xiao; Junming Chen; Yuejian Wang
Journal:  Eur Arch Otorhinolaryngol       Date:  2015-03-08       Impact factor: 2.503

Review 3.  The XprESS Multi-Sinus Dilation System for the Treatment of Chronic Sinusitis: A NICE Medical Technology Guidance.

Authors:  Michelle Jenks; Iain Willits; Emily Eaton Turner; Neil Hewitt; Mick Arber; Helen Cole; Joyce Craig; Andrew Sims
Journal:  Appl Health Econ Health Policy       Date:  2017-10       Impact factor: 2.561

4.  Hydraulic dissection technique during endoscopic sinus surgery using a novel balloon sinus dilation device.

Authors:  Isaac L Schmale; William C Yao; Martin J Citardi
Journal:  Laryngoscope Investig Otolaryngol       Date:  2021-08-19

5.  The enlargement of the maxillary ostium after balloon sinuplasty evaluated by a novel measuring technique from 3D CBCT images.

Authors:  Eerika Kalliomäki; Argyro J Bizaki-Vallaskangas; Olli Valtonen; Markus Rautiainen
Journal:  Sci Rep       Date:  2021-12-08       Impact factor: 4.379

  5 in total