Literature DB >> 23420332

A false positive fluorodeoxyglucose lymphadenopathy in a patient with pulmonary carcinoid tumor and previous breast reconstruction after bilateral mastectomy.

Andrea Billè1, Lara Girelli, Francesco Leo, Ugo Pastorino.   

Abstract

We present a case of a 60-year-old woman with a positive fluorodeoxyglucose integrated positron emission tomography and computed tomography (PET/TC) mammary chain lymphadenopathy and carcinoid tumor of the left lower lobe who had a previous bilateral mastectomy and breast reconstruction for breast cancer. She underwent a right muscle sparing mini-thoracotomy and mammary chain lymphadenectomy; the final histopathology showed granulomatous reaction to silicone.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23420332     DOI: 10.1007/s11748-013-0223-7

Source DB:  PubMed          Journal:  Gen Thorac Cardiovasc Surg        ISSN: 1863-6705


  5 in total

1.  Siliconomas mimicking cancer.

Authors:  Ahuva Grubstein; Maya Cohen; Adam Steinmetz; David Cohen
Journal:  Clin Imaging       Date:  2011 May-Jun       Impact factor: 1.605

2.  Detection of cancer in augmented breasts by positron emission tomography.

Authors:  D Y Noh; I J Yun; H S Kang; Y C Kim; J S Kim; J K Chung; D S Lee; M C Lee; W K Moon; Y K Youn; S K Oh; K J Choe
Journal:  Eur J Surg       Date:  1999-09

3.  Release of low molecular weight silicones and platinum from silicone breast implants.

Authors:  E D Lykissa; S V Kala; J B Hurley; R M Lebovitz
Journal:  Anal Chem       Date:  1997-12-01       Impact factor: 6.986

4.  A false positive F-FDG PET/CT scan caused by breast silicone injection.

Authors:  Chao-Jung Chen; Bi-Fang Lee; Wei-Jen Yao; Pei-Shan Wu; Wen-Chung Chen; Shu-Lin Peng; Nan-Tsing Chiu
Journal:  Korean J Radiol       Date:  2009-03-03       Impact factor: 3.500

5.  A false-positive fluorodeoxyglucose positron emission tomography (FDG-PET) imaging result for a patient after augmentation mammaplasty.

Authors:  Kyoko Kobe; Takafumi Chin; Ritsu Aoki; Hiko Hyakusoku
Journal:  Aesthetic Plast Surg       Date:  2009-05-07       Impact factor: 2.326

  5 in total
  1 in total

1.  Surgical strategy for aortic prosthetic graft infection with (18)F-fluorodeoxyglucose positron emission tomography/computed tomography.

Authors:  Katsuhiro Yamanaka; Takashi Matsueda; Shunsuke Miyahara; Yoshikatsu Nomura; Toshihito Sakamoto; Naoto Morimoto; Takeshi Inoue; Masamichi Matsumori; Kenji Okada; Yutaka Okita
Journal:  Gen Thorac Cardiovasc Surg       Date:  2015-01-08
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.