Literature DB >> 23417332

CGE-laser induced fluorescence of double-stranded DNA fragments using GelGreen dye.

Alberto Valdés1, Virginia García-Cañas, Alejandro Cifuentes.   

Abstract

Nowadays, new solutions focused on the replacement of reagents hazardous to human health are highly demanded in laboratories and Green Chemistry. In the present work, GelGreen, a new nonhazardous DNA staining reagent, has been assayed for the first time to analyze double-stranded DNA by CGE with LIF detection. The effect of GelGreen concentration on S/N ratio and migration time of a wide concentration range of standard DNA mixtures was evaluated. Under optimum GelGreen concentration in the sieving buffer efficient and sensitive separations of DNA fragments with sizes from 100-500 base pairs (bp) were obtained. A comparison in terms of resolution, time of analysis, LOD, LOQ, reproducibility, sizing performance, and cost of analysis was established between two optimized CGE-LIF protocols for DNA analysis, one based on the dye YOPRO-1 (typically used for CGE-LIF of DNA fragments) and another one using the new GelGreen. Analyses using YOPRO-1 were faster than those using GelGreen (ca. 31 min versus 34 min for the analysis of 100-500 bp DNA fragments). On the other side, sensitivity using GelGreen was twofold higher than that using YOPRO-1. The cost of analysis was significantly cheaper (ninefold) using GelGreen than with YOPRO-1. The resolution values and sizing performance were not significantly different between the two dyes (e.g. both dyes allowed the separation of fragments differing in only 2 bp in the 100-200 bp range). The usefulness of the separation method using GelGreen is demonstrated by the characterization of different amplicons obtained by PCR.
© 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23417332     DOI: 10.1002/elps.201200624

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  2 in total

1.  A DNA-modified hydrogel for simultaneous purification, concentration and detection of targeted cfDNA in human serum.

Authors:  Xinglu Jiang; Chenggui Zhao; Xiaobo Fan; Wei Xu; Rui Zhang; Hongbo Xu; Guoqiu Wu
Journal:  RSC Adv       Date:  2019-01-25       Impact factor: 4.036

2.  Gel electrophoresis in a polyvinylalcohol coated fused silica capillary for purity assessment of modified and secondary-structured oligo- and polyribonucleotides.

Authors:  Martyna Barciszewska; Agnieszka Sucha; Sandra Bałabańska; Marcin K Chmielewski
Journal:  Sci Rep       Date:  2016-01-18       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.