BACKGROUND: With physical inactivity inextricably linked to the increasing prevalence of obesity, there is a need for validated methods that measure free-living energy expenditure (EE) within sedentary environments. While accelerometers enable these measurements, few studies have compared device accuracy in such settings. The aim of this study was to investigate the relative validity of the Actigraph, RT3 and SenseWear Armband (SWA). METHODS: Twenty-three (11 male, 12 female) participants (age: 25.3 ± 6.3 yr; BMI: 22.6 ± 2.7) wore 3 accelerometers at designated sites during a 4-hour stay in the Whole Room Calorimeter (WRC). Participants performed 2 10-minute bouts of light-intensity exercise (stepping and stationary cycling) and engaged in unstructured sedentary activities. EE estimated by accelerometers was compared with WRC EE derived from measurements of gaseous exchange. RESULTS: The Actigraph and SWA both accurately estimated EE during the stepping exercise. EE estimated by the RT3 during stepping was significantly lower than the WRC value (31.2% ± 15.6%, P < .001). All accelerometers underestimated cycling and unstructured activity EE over the trial period (P < .001). CONCLUSIONS: The Actigraph and SWA are both valid tools for quantifying EE during light-intensity stepping. These results provide further valuable information on how accelerometer devices may be appropriately used.
BACKGROUND: With physical inactivity inextricably linked to the increasing prevalence of obesity, there is a need for validated methods that measure free-living energy expenditure (EE) within sedentary environments. While accelerometers enable these measurements, few studies have compared device accuracy in such settings. The aim of this study was to investigate the relative validity of the Actigraph, RT3 and SenseWear Armband (SWA). METHODS: Twenty-three (11 male, 12 female) participants (age: 25.3 ± 6.3 yr; BMI: 22.6 ± 2.7) wore 3 accelerometers at designated sites during a 4-hour stay in the Whole Room Calorimeter (WRC). Participants performed 2 10-minute bouts of light-intensity exercise (stepping and stationary cycling) and engaged in unstructured sedentary activities. EE estimated by accelerometers was compared with WRC EE derived from measurements of gaseous exchange. RESULTS: The Actigraph and SWA both accurately estimated EE during the stepping exercise. EE estimated by the RT3 during stepping was significantly lower than the WRC value (31.2% ± 15.6%, P < .001). All accelerometers underestimated cycling and unstructured activity EE over the trial period (P < .001). CONCLUSIONS: The Actigraph and SWA are both valid tools for quantifying EE during light-intensity stepping. These results provide further valuable information on how accelerometer devices may be appropriately used.
Authors: John B Correa; John W Apolzan; Desti N Shepard; Daniel P Heil; Jennifer C Rood; Corby K Martin Journal: Appl Physiol Nutr Metab Date: 2016-03-14 Impact factor: 2.665
Authors: Bonny Rockette-Wagner; Kristi L Storti; Dana Dabelea; Sharon Edelstein; Hermes Florez; Paul W Franks; Maria G Montez; Jeremy Pomeroy; Andrea M Kriska Journal: Am J Prev Med Date: 2016-11-22 Impact factor: 5.043
Authors: Renae J McNamara; Ling Ling Y Tsai; Sally L Wootton; L W Cindy Ng; Marita T Dale; Zoe J McKeough; Jennifer A Alison Journal: Chron Respir Dis Date: 2016-02-15 Impact factor: 2.444
Authors: Youngwon Kim; Paul Hibbing; Pedro F Saint-Maurice; Laura D Ellingson; Erin Hennessy; Dana L Wolff-Hughes; Frank M Perna; Gregory J Welk Journal: Am J Prev Med Date: 2017-06 Impact factor: 5.043
Authors: Dale S Bond; J Graham Thomas; Kevin C O'Leary; Richard B Lipton; B Lee Peterlin; Julie Roth; Lucille Rathier; Rena R Wing Journal: Cephalalgia Date: 2014-12-04 Impact factor: 6.292
Authors: Cille H Sevild; Christopher P Niemiec; Sindre M Dyrstad; Lars Edvin Bru Journal: Int J Environ Res Public Health Date: 2022-04-24 Impact factor: 4.614
Authors: Gustavo J Almeida; Lauren Terhorst; James J Irrgang; G Kelley Fitzgerald; John M Jakicic; Sara R Piva Journal: J Exerc Sports Orthop Date: 2017-12-06