| Literature DB >> 2341285 |
Abstract
Reproducibility of gastric emptying (GE) of a radiolabelled solid meal was assessed. The short-term reproducibility was evaluated on the basis of 12 paired GE examinations performed 1-3 days apart. Twelve paired GE examinations taken 3-8 months apart enabled long-term reproducibility assessment. Reproducibility of GE parameters was expressed in terms of the coefficient of variation, CV. No significant between-day variation of solid GE was found either regarding the short-term or the long-term reproducibility. Although slightly higher CV values characterized the long-term reproducibility of the GE parameters considered, the variations of the differences between repeated GE examinations did not differ significantly between short- and long-term GE reproducibility. The results obtained justify the use of radioisotopic GE measurement for the assessment of early and late results of pharmacologic or surgical management.Mesh:
Substances:
Year: 1990 PMID: 2341285 DOI: 10.1016/0883-2897(90)90056-7
Source DB: PubMed Journal: Int J Rad Appl Instrum B ISSN: 0883-2897