Low recurrence rate and low chronic pain associated with inguinal hernia repair by laparoscopic placement of Parietex ProGrip™ mesh: clinical outcomes of 220 hernias with mean follow-up at 23 months.

D Birk1, S Hess, C Garcia-Pardo.   

Abstract

INTRODUCTION: The aim of this study was to demonstrate the safety and the efficacy of the self-gripping Parietex ProGrip™ mesh (Sofradim Production, Trévoux, France) used with the laparoscopic approach for inguinal hernia repair. The incidence of chronic pain, post-operative complications, patient satisfaction and hernia recurrence at follow-up after 12 months was evaluated.
METHODS: Data were collected retrospectively from patient files and were analyzed for 169 male and female patients with 220 primary inguinal hernias. All patients included had undergone surgical repair for inguinal hernia by the laparoscopic transabdominal preperitoneal approach using Parietex ProGrip™ meshes performed in the same clinical center in Germany. Pre-, per- and post-operative data were collected, and a follow-up after 12 months was performed prospectively. Complications, pain scored on a 0-10 numeric rating scale (NRS), patient satisfaction and hernia recurrence were assessed.
RESULTS: The only complications were minor and were post-operative: hematoma/seroma (3 cases), secondary hemorrhage through the trocar's site (2 cases), hematuria, emphysema in the inguinal regions (both sides) and swelling above the genital organs (1 case for each). At mean follow-up at 22.8 months, there were only 3 reports of hernia recurrence: 1.4 % of the hernias. Most patients (95.9 %) were satisfied or very satisfied with their hernia repair with only 1.2 % reporting severe pain (NRS score 7-10) and 3.6 % reported mild pain.
CONCLUSION: This study demonstrates that in experienced hands, inguinal hernia repair surgery performed by laparoscopic transabdominal preperitoneal hernioplasty using Parietex ProGrip™ self-gripping meshes is rapid, efficient and safe with low pain and low hernia recurrence rate.

Entities:  

Mesh:

Year:  2013        PMID: 23412779     DOI: 10.1007/s10029-013-1053-3

Source DB:  PubMed          Journal:  Hernia        ISSN: 1248-9204            Impact factor:   4.739


  29 in total

1.  Randomized controlled multicenter international clinical trial of self-gripping Parietex™ ProGrip™ polyester mesh versus lightweight polypropylene mesh in open inguinal hernia repair: interim results at 3 months.

Authors:  A Kingsnorth; M Gingell-Littlejohn; S Nienhuijs; S Schüle; P Appel; P Ziprin; A Eklund; M Miserez; S Smeds
Journal:  Hernia       Date:  2012-03-28       Impact factor: 4.739

2.  Mesh fixation with human fibrin glue (Tissucol) in open tension-free inguinal hernia repair: a preliminary report.

Authors:  S Canonico; A Santoriello; F Campitiello; A Fattopace; A Della Corte; I Sordelli; R Benevento
Journal:  Hernia       Date:  2005-08-17       Impact factor: 4.739

3.  Long-term cost-minimization analysis comparing laparoscopic with open (Lichtenstein) inguinal hernia repair.

Authors:  A Eklund; P Carlsson; A Rosenblad; A Montgomery; L Bergkvist; C Rudberg
Journal:  Br J Surg       Date:  2010-05       Impact factor: 6.939

4.  Predictive risk factors for persistent postherniotomy pain.

Authors:  Eske K Aasvang; Eliza Gmaehle; Jeanette B Hansen; Bjorn Gmaehle; Julie L Forman; Jochen Schwarz; Reinhard Bittner; Henrik Kehlet
Journal:  Anesthesiology       Date:  2010-04       Impact factor: 7.892

5.  Comparison of institutional costs for laparoscopic preperitoneal inguinal hernia versus open repair and its reimbursement in an ambulatory surgery center.

Authors:  Volker R Jacobs; John E Morrison
Journal:  Surg Laparosc Endosc Percutan Tech       Date:  2008-02       Impact factor: 1.719

6.  Open mesh versus laparoscopic mesh repair of inguinal hernia.

Authors:  Leigh Neumayer; Anita Giobbie-Hurder; Olga Jonasson; Robert Fitzgibbons; Dorothy Dunlop; James Gibbs; Domenic Reda; William Henderson
Journal:  N Engl J Med       Date:  2004-04-25       Impact factor: 91.245

7.  European Hernia Society guidelines on the treatment of inguinal hernia in adult patients.

Authors:  M P Simons; T Aufenacker; M Bay-Nielsen; J L Bouillot; G Campanelli; J Conze; D de Lange; R Fortelny; T Heikkinen; A Kingsnorth; J Kukleta; S Morales-Conde; P Nordin; V Schumpelick; S Smedberg; M Smietanski; G Weber; M Miserez
Journal:  Hernia       Date:  2009-07-28       Impact factor: 4.739

8.  A critical evaluation of the Lichtenstein tension-free hernioplasty.

Authors:  P K Amid; A G Shulman; I L Lichtenstein
Journal:  Int Surg       Date:  1994 Jan-Mar

9.  Meta-analysis of randomized clinical trials comparing open and laparoscopic inguinal hernia repair.

Authors:  M A Memon; N J Cooper; B Memon; M I Memon; K R Abrams
Journal:  Br J Surg       Date:  2003-12       Impact factor: 6.939

10.  Laparoscopic ventral hernia repair is safe and cost effective.

Authors:  G Beldi; R Ipaktchi; M Wagner; B Gloor; D Candinas
Journal:  Surg Endosc       Date:  2005-12-07       Impact factor: 3.453

View more
  25 in total

1.  Invited commentary: Persistent pain after inguinal hernia repair: what do we know and what do we need to know?

Authors:  H Kehlet; R M Roumen; W Reinpold; M Miserez
Journal:  Hernia       Date:  2013-05-21       Impact factor: 4.739

2.  A novel sutureless colonic anastomosis with self-gripping mesh: an experimental model.

Authors:  Gokhan Cipe; Fatma Umit Malya; Mustafa Hasbahceci; Pinar Atukeren; Nur Buyukpinarbasili; Oğuzhan Karatepe; Mahmut Muslumanoglu
Journal:  Int J Clin Exp Med       Date:  2014-05-15

Review 3.  [Recurrence after hernia surgery: complication or natural course?].

Authors:  A Kohler; G Beldi
Journal:  Chirurg       Date:  2014-02       Impact factor: 0.955

4.  A cost effective approach to laparoscopic transabdominal preperitoneal hernia repair.

Authors:  P Cathcart; T Hettiarachchi; T Sathesh-Kumar
Journal:  Ann R Coll Surg Engl       Date:  2014-10       Impact factor: 1.891

5.  Improved immediate postoperative pain following laparoscopic inguinal herniorrhaphy using self-adhering mesh.

Authors:  Daniel G Davila; Melissa C Helm; Irene S Pourladian; Matthew J Frelich; Andrew S Kastenmeier; Jon C Gould; Matthew I Goldblatt
Journal:  Surg Endosc       Date:  2017-08-24       Impact factor: 4.584

6.  Perioperative outcomes and costs of laparoscopic versus open inguinal hernia repair.

Authors:  C Tadaki; D Lomelin; A Simorov; R Jones; M Humphreys; M daSilva; S Choudhury; V Shostrom; E Boilesen; V Kothari; D Oleynikov; M Goede
Journal:  Hernia       Date:  2016-02-13       Impact factor: 4.739

7.  A comparison of Progrip(®) and Adhesix (®) self-adhering hernia meshes in an onlay model in the rat.

Authors:  S Gruber-Blum; N Riepl; J Brand; C Keibl; H Redl; R H Fortelny; A H Petter-Puchner
Journal:  Hernia       Date:  2014-05-06       Impact factor: 4.739

8.  Long-term follow-up of laparoscopic total extraperitoneal (TEP) repair in inguinal hernia without mesh fixation.

Authors:  S Golani; P Middleton
Journal:  Hernia       Date:  2016-12-26       Impact factor: 4.739

9.  How I do it: the horizontal-bilateral unfolding method for self-gripping (Progrip™) mesh placement in laparoscopic inguinal hernia repair.

Authors:  J Li; X Shao; T Cheng
Journal:  Hernia       Date:  2019-01-31       Impact factor: 4.739

Review 10.  Causes of recurrence in laparoscopic inguinal hernia repair.

Authors:  Manjunath Siddaiah-Subramanya; Darius Ashrafi; Breda Memon; Muhammed Ashraf Memon
Journal:  Hernia       Date:  2018-08-25       Impact factor: 4.739

View more