Literature DB >> 23412297

Seven-year results of a press-fit, hydroxyapatite-coated double mobility acetabular component in patients aged 65 years or older.

Pierre-Luc Fresard1, Charles Alvherne, Jean-Loup Cartier, Patrick Cuinet, Jean-Pierre Lantuejoul.   

Abstract

One hundred and thirty-four THA were done between 1998 and 2002 with AVANTAGE(®) Press-Fit double mobility cup. The mean age of patients was 74 ± 6 years (range 65-94 years). The mean follow-up was 5.4 years (range, 0.15-10 years). The mean preoperative Harris Hip Score was 51.3 ± 14 versus 88 ± 12, at the latest follow-up, and the mean Merle d'Aubigné hip functional score was 8 ± 3 versus 16.3 ± 2.91; patients (68 %) were alive at a mean of 7.2 years postoperatively (range, 5-10 years). Three revisions were documented for aseptic loosening. The overall survival rate at 7.2 years was 96.3 % (95 % confidence interval 92.2-100) using cup revision for aseptic loosening as the end point.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 23412297     DOI: 10.1007/s00590-012-0991-2

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  15 in total

1.  Femoral head size is a risk factor for total hip luxation: a study of 42,987 primary hip arthroplasties from the Norwegian Arthroplasty Register.

Authors:  Sven Byström; Birgitte Espehaug; Ove Furnes; Leif I Havelin
Journal:  Acta Orthop Scand       Date:  2003-10

2.  [Dual articulation retentive acetabular liners and wear: surface analysis of 40 retrieved polyethylene implants].

Authors:  P Adam; F Farizon; M-H Fessy
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  2005-11

3.  [Survival of cementless dual mobility sockets: ten-year follow-up].

Authors:  R Philippot; P Adam; F Farizon; M H Fessy; G Bousquet
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  2006-06

4.  [Numerical evaluation of hip function].

Authors:  R Merle D'Augibné
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  1970 Jul-Aug

5.  Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation.

Authors:  W H Harris
Journal:  J Bone Joint Surg Am       Date:  1969-06       Impact factor: 5.284

6.  An analysis of the risk of hip dislocation with a contemporary total joint registry.

Authors:  Monti Khatod; Thomas Barber; Elizabeth Paxton; Robert Namba; Donald Fithian
Journal:  Clin Orthop Relat Res       Date:  2006-06       Impact factor: 4.176

7.  Incidence rates of dislocation, pulmonary embolism, and deep infection during the first six months after elective total hip replacement.

Authors:  Charlotte B Phillips; Jane A Barrett; Elena Losina; Nizar N Mahomed; Elizabeth A Lingard; Edward Guadagnoli; John A Baron; William H Harris; Robert Poss; Jeffrey N Katz
Journal:  J Bone Joint Surg Am       Date:  2003-01       Impact factor: 5.284

8.  [Results of the Evora dual mobility socket: five years follow-up].

Authors:  S Leclercq; J-Y Benoit; J-P de Rosa; P Euvrard; C Leteurtre; P Girardin
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  2008-02-01

9.  Dislocations after total hip arthroplasty.

Authors:  R Y Woo; B F Morrey
Journal:  J Bone Joint Surg Am       Date:  1982-12       Impact factor: 5.284

10.  Recurrent and non-recurrent dislocation following total hip arthroplasty.

Authors:  H O Lindberg; A S Carlsson; C F Gentz; H Pettersson
Journal:  Acta Orthop Scand       Date:  1982-12
View more
  3 in total

1.  Obesity is no longer a risk factor for dislocation after total hip arthroplasty with a double-mobility cup.

Authors:  Paul Maisongrosse; Benoit Lepage; Etienne Cavaignac; Régis Pailhe; Nicolas Reina; Philippe Chiron; Jean-Michel Laffosse
Journal:  Int Orthop       Date:  2014-12-31       Impact factor: 3.075

2.  Early intraprosthetic dislocation in dual-mobility implants: a systematic review.

Authors:  Ivan De Martino; Rocco D'Apolito; Bradford S Waddell; Alexander S McLawhorn; Peter K Sculco; Thomas P Sculco
Journal:  Arthroplast Today       Date:  2017-02-05

3.  Study protocol: Effectiveness of dual-mobility cups compared with uni-polar cups for preventing dislocation after primary total hip arthroplasty in elderly patients - design of a randomized controlled trial nested in the Dutch Arthroplasty Registry.

Authors:  Loes W A H Van Beers; Bart C H Van Der Wal; Tess Glastra Van Loon; Dirk Jan F Moojen; Marieke F Van Wier; Amanda D Klaassen; Nienke W Willigenburg; Rudolf W Poolman
Journal:  Acta Orthop       Date:  2020-08-04       Impact factor: 3.717

  3 in total