Literature DB >> 23411879

Otago glaucoma surgery outcome study: comparative results for the 175-mm2 Molteno3 and double-plate molteno implants.

Andrew M Thompson1, Anthony C B Molteno, Tui H Bevin, Peter Herbison.   

Abstract

OBJECTIVE: To evaluate the efficacy of the 175-mm2 Molteno3 implant in patients with nonneovascular glaucoma.
METHODS: A hospital-based, retrospective historical control comparative case series comparing results in the first 87 eyes to receive the 175-mm(2) Molteno3 implant with those in a control group of 115 eyes receiving the 274-mm(2) double-plate Molteno implant.
RESULTS: Success was defined as an intraocular pressure (IOP) of at least 6 mm Hg but not more than 21 mm Hg with or without hypotensive medication. The mean postoperative follow-up was 3.0 years (range, 13 days to 5.6 years) in the Molteno3 implant group and 6.2 years (range, 1 day to 13.9 years) in the double-plate Molteno implant group. The mean (SD) preoperative IOP was 25.6 (7.1) mm Hg in the Molteno3 implant group in eyes treated with a mean of 2.3 ocular hypotensive medications, and 25.7 (8.0) mm Hg in the double-plate Molteno implant group in eyes treated with a mean of 2.2 medications. The mean (SD) postoperative IOP at 36 months was 13.9 (3.2) mm Hg in the Molteno3 implant group in eyes treated with a mean of 0.9 ocular hypotensive medications, and 14.5 (3.4) mm Hg in the double-plate group in eyes treated with a mean of 0.7 medications. The probability of IOP control at 3 years was 0.79 in both groups. There was significantly more postoperative hypotony in eyes without a polyglactin 910 tie in the Molteno3 implant group (P= .04); however, significantly more eyes with flat anterior chambers in the double-plate group required anterior chamber reformation (P= .03).
CONCLUSION: The 175-mm(2) Molteno3 implant provided intermediate-term successful treatment of nonneovascular glaucoma comparable to that provided by the double-plate Molteno implant.

Entities:  

Mesh:

Year:  2013        PMID: 23411879     DOI: 10.1001/2013.jamaophthalmol.165

Source DB:  PubMed          Journal:  JAMA Ophthalmol        ISSN: 2168-6165            Impact factor:   7.389


  4 in total

Review 1.  Aqueous shunts for glaucoma.

Authors:  Victoria L Tseng; Anne L Coleman; Melinda Y Chang; Joseph Caprioli
Journal:  Cochrane Database Syst Rev       Date:  2017-07-28

2.  European Glaucoma Society Terminology and Guidelines for Glaucoma, 4th Edition - Chapter 3: Treatment principles and options Supported by the EGS Foundation: Part 1: Foreword; Introduction; Glossary; Chapter 3 Treatment principles and options.

Authors: 
Journal:  Br J Ophthalmol       Date:  2017-06       Impact factor: 4.638

3.  Risk Factors for Failure in Double-Plate Tube Surgery for Refractory Glaucoma: 25 Years Surgical Experience.

Authors:  Susana Duch; Carlos A Arciniegas-Perasso; Stefania Piludu; Shirin Djavanmardi; Elena Milla
Journal:  Clin Ophthalmol       Date:  2021-02-09

4.  Molteno3 implantation as primary glaucoma surgery.

Authors:  Juha O Välimäki; Ari-Pekka A Ylilehto
Journal:  J Ophthalmol       Date:  2014-03-11       Impact factor: 1.909

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.